不同类型绝缘子串在典型污染成分下的电性能

Yang Zhongyi, Xingliang Jiang, Zhijin Zhang, Dongdong Zhang, Liu Youchao
{"title":"不同类型绝缘子串在典型污染成分下的电性能","authors":"Yang Zhongyi, Xingliang Jiang, Zhijin Zhang, Dongdong Zhang, Liu Youchao","doi":"10.1109/CEIDP.2015.7352025","DOIUrl":null,"url":null,"abstract":"The external insulation contamination on real transmission line is mainly composed by the mixture of NaCl, CaSO4 and other various kinds of constituents. Different constituents have effects on the flashover performance of various types insulator, but it is still not considered by the existing standard about external insulation design in polluted region. This paper investigated the electrical property of different types of insulator string under typical pollution constituents. During the tests, the insulator samples were polluted by NaCl, CaSO4 and mixture pollution constituents in representative region respectively. The flashover data was obtained and then the waste rate of insulation were calculated based on pollution withstand voltage method. Research results indicate that, The characteristic b of ceramic, glass and composite insulator under mixture constituents pollution is obviously lower than that under NaCl, traditional design method overrates the influence of ESDD on flashover performance; the electrical property of applied insulator under mixture pollution constituents should be studied to provide better reference for the external insulation design; When using the pollution withstand method to design the external insulation, the leakage distance of insulation should be chosen basing on the mixture pollution constituents in practical region.","PeriodicalId":432404,"journal":{"name":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"46 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Electrical property of different types insulator string under typical pollution constituents\",\"authors\":\"Yang Zhongyi, Xingliang Jiang, Zhijin Zhang, Dongdong Zhang, Liu Youchao\",\"doi\":\"10.1109/CEIDP.2015.7352025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The external insulation contamination on real transmission line is mainly composed by the mixture of NaCl, CaSO4 and other various kinds of constituents. Different constituents have effects on the flashover performance of various types insulator, but it is still not considered by the existing standard about external insulation design in polluted region. This paper investigated the electrical property of different types of insulator string under typical pollution constituents. During the tests, the insulator samples were polluted by NaCl, CaSO4 and mixture pollution constituents in representative region respectively. The flashover data was obtained and then the waste rate of insulation were calculated based on pollution withstand voltage method. Research results indicate that, The characteristic b of ceramic, glass and composite insulator under mixture constituents pollution is obviously lower than that under NaCl, traditional design method overrates the influence of ESDD on flashover performance; the electrical property of applied insulator under mixture pollution constituents should be studied to provide better reference for the external insulation design; When using the pollution withstand method to design the external insulation, the leakage distance of insulation should be chosen basing on the mixture pollution constituents in practical region.\",\"PeriodicalId\":432404,\"journal\":{\"name\":\"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"volume\":\"46 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2015.7352025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2015.7352025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

实际输电线路的外绝缘污染主要由NaCl、CaSO4等多种成分混合而成。不同成分对不同类型绝缘子的闪络性能有影响,但现行的污染地区外绝缘设计标准尚未考虑到这一点。研究了不同类型绝缘子串在典型污染成分下的电性能。试验过程中,绝缘子样品分别在有代表性的区域受到NaCl、CaSO4和混合污染成分的污染。在获得闪络数据的基础上,采用耐污电压法计算了绝缘的废率。研究结果表明:陶瓷、玻璃和复合绝缘子在混合成分污染下的特性b明显低于NaCl污染下的特性b,传统设计方法高估了ESDD对闪络性能的影响;研究外加绝缘子在混合污染组分下的电性能,为外绝缘设计提供更好的参考;采用耐污法设计外绝缘时,应根据实际区域的混合污染成分选择绝缘泄漏距离。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrical property of different types insulator string under typical pollution constituents
The external insulation contamination on real transmission line is mainly composed by the mixture of NaCl, CaSO4 and other various kinds of constituents. Different constituents have effects on the flashover performance of various types insulator, but it is still not considered by the existing standard about external insulation design in polluted region. This paper investigated the electrical property of different types of insulator string under typical pollution constituents. During the tests, the insulator samples were polluted by NaCl, CaSO4 and mixture pollution constituents in representative region respectively. The flashover data was obtained and then the waste rate of insulation were calculated based on pollution withstand voltage method. Research results indicate that, The characteristic b of ceramic, glass and composite insulator under mixture constituents pollution is obviously lower than that under NaCl, traditional design method overrates the influence of ESDD on flashover performance; the electrical property of applied insulator under mixture pollution constituents should be studied to provide better reference for the external insulation design; When using the pollution withstand method to design the external insulation, the leakage distance of insulation should be chosen basing on the mixture pollution constituents in practical region.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信