关于户内电网导体材料允许横截面的选择

I. Naumov
{"title":"关于户内电网导体材料允许横截面的选择","authors":"I. Naumov","doi":"10.21285/2227-2917-2022-4-589-599","DOIUrl":null,"url":null,"abstract":"In this work, a software package was developed in order to investigate the applicability of conductors having different cross-sections for installing internal electrical networks in individual households. A combination of general scientific methods, including circuit theory, numerical analysis and visualisation using MATLAB graphical editor, was used. The state of individual households in the Irkutsk region was analysed. It was confirmed that one of the most common causes of combustion associated with the construction of internal electrical networks of individual households involves unbalanced phase cur-rents, leading to additional heat losses, which give rise to fire hazards. A thermal calculation of the electric network functioning under normal operating conditions was carried out in order to obtain ex-pressions for determining the maximum permissible values of the neutral conductor current of the in-ternal electrical network of the house. These algorithms and programs were used to tabulate the limit values of the zero sequence currents for different cross-sections of the conductor material and tem-perature ranges. The efficiency of using balanced/unbalanced converters to mitigate the negative ef-fects of unbalanced power consumption was demonstrated by a field test. It can be concluded that one of the most efficient ways to reduce fire hazards in individual houses involves balancing the operating modes of the internal electrical network. The obtained data may therefore be used by construction or-ganisations, as well as the Ministry of Emergency Situations of the Russian Federation, which monitors the fire safety of individual houses.","PeriodicalId":119410,"journal":{"name":"«Izvestiya vuzov. Investitsiyi. Stroyitelstvo. Nedvizhimost»","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the choice of allowable cross-sections of conductor material in internal electrical networks when building individual households\",\"authors\":\"I. Naumov\",\"doi\":\"10.21285/2227-2917-2022-4-589-599\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, a software package was developed in order to investigate the applicability of conductors having different cross-sections for installing internal electrical networks in individual households. A combination of general scientific methods, including circuit theory, numerical analysis and visualisation using MATLAB graphical editor, was used. The state of individual households in the Irkutsk region was analysed. It was confirmed that one of the most common causes of combustion associated with the construction of internal electrical networks of individual households involves unbalanced phase cur-rents, leading to additional heat losses, which give rise to fire hazards. A thermal calculation of the electric network functioning under normal operating conditions was carried out in order to obtain ex-pressions for determining the maximum permissible values of the neutral conductor current of the in-ternal electrical network of the house. These algorithms and programs were used to tabulate the limit values of the zero sequence currents for different cross-sections of the conductor material and tem-perature ranges. The efficiency of using balanced/unbalanced converters to mitigate the negative ef-fects of unbalanced power consumption was demonstrated by a field test. It can be concluded that one of the most efficient ways to reduce fire hazards in individual houses involves balancing the operating modes of the internal electrical network. The obtained data may therefore be used by construction or-ganisations, as well as the Ministry of Emergency Situations of the Russian Federation, which monitors the fire safety of individual houses.\",\"PeriodicalId\":119410,\"journal\":{\"name\":\"«Izvestiya vuzov. Investitsiyi. Stroyitelstvo. Nedvizhimost»\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"«Izvestiya vuzov. Investitsiyi. Stroyitelstvo. Nedvizhimost»\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21285/2227-2917-2022-4-589-599\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"«Izvestiya vuzov. Investitsiyi. Stroyitelstvo. Nedvizhimost»","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21285/2227-2917-2022-4-589-599","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项工作中,开发了一个软件包,以调查具有不同横截面的导体在单个家庭中安装内部电网的适用性。结合了一般的科学方法,包括电路理论、数值分析和使用MATLAB图形编辑器进行可视化。分析了伊尔库茨克地区个别家庭的状况。经证实,与个别家庭内部电网建设有关的最常见燃烧原因之一涉及相电流不平衡,导致额外的热量损失,从而引起火灾危险。对正常运行条件下的电网进行了热计算,以获得用于确定房屋内部电网中性导体电流最大允许值的表达式。这些算法和程序被用于制表零序电流在不同导体材料截面和温度范围下的极限值。通过现场测试,证明了使用平衡/不平衡转换器减轻不平衡功耗负面影响的效率。可以得出结论,减少单个房屋火灾危险的最有效方法之一是平衡内部电网的运行模式。因此,获得的数据可由建筑组织以及监测个别房屋消防安全的俄罗斯联邦紧急情况部使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the choice of allowable cross-sections of conductor material in internal electrical networks when building individual households
In this work, a software package was developed in order to investigate the applicability of conductors having different cross-sections for installing internal electrical networks in individual households. A combination of general scientific methods, including circuit theory, numerical analysis and visualisation using MATLAB graphical editor, was used. The state of individual households in the Irkutsk region was analysed. It was confirmed that one of the most common causes of combustion associated with the construction of internal electrical networks of individual households involves unbalanced phase cur-rents, leading to additional heat losses, which give rise to fire hazards. A thermal calculation of the electric network functioning under normal operating conditions was carried out in order to obtain ex-pressions for determining the maximum permissible values of the neutral conductor current of the in-ternal electrical network of the house. These algorithms and programs were used to tabulate the limit values of the zero sequence currents for different cross-sections of the conductor material and tem-perature ranges. The efficiency of using balanced/unbalanced converters to mitigate the negative ef-fects of unbalanced power consumption was demonstrated by a field test. It can be concluded that one of the most efficient ways to reduce fire hazards in individual houses involves balancing the operating modes of the internal electrical network. The obtained data may therefore be used by construction or-ganisations, as well as the Ministry of Emergency Situations of the Russian Federation, which monitors the fire safety of individual houses.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信