{"title":"高压直流单极接地运行方式对变压器及保护的影响研究","authors":"Yang Yu, Z. Hao, Baohui Zhang, Bo Zhi-qian","doi":"10.1109/UPEC.2008.4651479","DOIUrl":null,"url":null,"abstract":"The neutral point potential of the grounding transformer will be changed when HVDC system operates in a dc monopole ground return mode and dc bias may be generated. Dc bias will change exciting currentdasias waveform. Then large quantity of even and odd harmonics will be produced. The harmonics will do harm to the transformer and its protection. This paper uses PSCAD/EMTDC to create a simulation model. It emulates exciting current of a practical 750 kV single-phase transformer in variant cases under dc bias. It studies the distortion of exciting current, harmonic distribution, the peak value of the exciting current under dc bias. Meanwhile, the performance of transformer protection in this harmonic environment is analyzed. The loss made by exciting currentpsilas distortion and elevated temperature rise of core tie-plate are quantitative calculated.","PeriodicalId":287461,"journal":{"name":"2008 43rd International Universities Power Engineering Conference","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"The effect research on transformers and protections under HVDC monopole ground operation mode\",\"authors\":\"Yang Yu, Z. Hao, Baohui Zhang, Bo Zhi-qian\",\"doi\":\"10.1109/UPEC.2008.4651479\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The neutral point potential of the grounding transformer will be changed when HVDC system operates in a dc monopole ground return mode and dc bias may be generated. Dc bias will change exciting currentdasias waveform. Then large quantity of even and odd harmonics will be produced. The harmonics will do harm to the transformer and its protection. This paper uses PSCAD/EMTDC to create a simulation model. It emulates exciting current of a practical 750 kV single-phase transformer in variant cases under dc bias. It studies the distortion of exciting current, harmonic distribution, the peak value of the exciting current under dc bias. Meanwhile, the performance of transformer protection in this harmonic environment is analyzed. The loss made by exciting currentpsilas distortion and elevated temperature rise of core tie-plate are quantitative calculated.\",\"PeriodicalId\":287461,\"journal\":{\"name\":\"2008 43rd International Universities Power Engineering Conference\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 43rd International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2008.4651479\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 43rd International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2008.4651479","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The effect research on transformers and protections under HVDC monopole ground operation mode
The neutral point potential of the grounding transformer will be changed when HVDC system operates in a dc monopole ground return mode and dc bias may be generated. Dc bias will change exciting currentdasias waveform. Then large quantity of even and odd harmonics will be produced. The harmonics will do harm to the transformer and its protection. This paper uses PSCAD/EMTDC to create a simulation model. It emulates exciting current of a practical 750 kV single-phase transformer in variant cases under dc bias. It studies the distortion of exciting current, harmonic distribution, the peak value of the exciting current under dc bias. Meanwhile, the performance of transformer protection in this harmonic environment is analyzed. The loss made by exciting currentpsilas distortion and elevated temperature rise of core tie-plate are quantitative calculated.