{"title":"60脉冲电压源变换器的新结构","authors":"W. Pan, Jing Zhang, Hairong Chen, Yong Chang, Chao Wang","doi":"10.1109/PES.2007.385943","DOIUrl":null,"url":null,"abstract":"The proposed voltage source converter is composed of a series double bridge converter with an auxiliary circuit. The auxiliary circuit injects DC voltage via the mid point of the double bridge converter. The injection ratio and frequency are chosen to convert the standard 12-pulse into 60-pulse configuration without PWM or increasing the number of bridges, thus the voltage and current harmonic can fulfill the THD limit without conventional filter. The converter is operated under fundamental frequency for the main bridges, thus its switching lose is low. The converter can be widely used in the STATCOM and HVDC system. The paper describes the principles and control strategies of the proposed converter. The operational feasibility of the proposed converter is verified by computer simulation using the PSCAD/EMTDC package.","PeriodicalId":380613,"journal":{"name":"2007 IEEE Power Engineering Society General Meeting","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Novel Configuration of 60-pulse Voltage Source Converter\",\"authors\":\"W. Pan, Jing Zhang, Hairong Chen, Yong Chang, Chao Wang\",\"doi\":\"10.1109/PES.2007.385943\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The proposed voltage source converter is composed of a series double bridge converter with an auxiliary circuit. The auxiliary circuit injects DC voltage via the mid point of the double bridge converter. The injection ratio and frequency are chosen to convert the standard 12-pulse into 60-pulse configuration without PWM or increasing the number of bridges, thus the voltage and current harmonic can fulfill the THD limit without conventional filter. The converter is operated under fundamental frequency for the main bridges, thus its switching lose is low. The converter can be widely used in the STATCOM and HVDC system. The paper describes the principles and control strategies of the proposed converter. The operational feasibility of the proposed converter is verified by computer simulation using the PSCAD/EMTDC package.\",\"PeriodicalId\":380613,\"journal\":{\"name\":\"2007 IEEE Power Engineering Society General Meeting\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2007.385943\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2007.385943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

所提出的电压源变换器由串联双桥变换器和辅助电路组成。辅助电路通过双桥变换器的中点注入直流电压。通过选择注入比和频率,将标准的12脉冲转换为60脉冲配置,无需PWM或增加桥的数量,从而使电压和电流谐波满足不需要常规滤波器的THD限制。该变换器工作在主桥的基频下,开关损耗小。该变换器可广泛应用于STATCOM和HVDC系统中。本文介绍了该变换器的工作原理和控制策略。利用PSCAD/EMTDC包进行了计算机仿真,验证了该转换器的运行可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Novel Configuration of 60-pulse Voltage Source Converter
The proposed voltage source converter is composed of a series double bridge converter with an auxiliary circuit. The auxiliary circuit injects DC voltage via the mid point of the double bridge converter. The injection ratio and frequency are chosen to convert the standard 12-pulse into 60-pulse configuration without PWM or increasing the number of bridges, thus the voltage and current harmonic can fulfill the THD limit without conventional filter. The converter is operated under fundamental frequency for the main bridges, thus its switching lose is low. The converter can be widely used in the STATCOM and HVDC system. The paper describes the principles and control strategies of the proposed converter. The operational feasibility of the proposed converter is verified by computer simulation using the PSCAD/EMTDC package.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信