{"title":"一组建筑物对雷电电磁场的影响","authors":"M. S. Vieira, J. M. Janiszewski","doi":"10.1109/SIPDA.2015.7339332","DOIUrl":null,"url":null,"abstract":"Among the various factors that influence the lightning electromagnetic fields, the presence of obstacles such as buildings has deserved some few studies. The paper presents the results related to the influence of a group of buildings on the vertical electric field, by a 3D FDTD code developed for a more complete study. Two rows of concrete buildings were considered, with different heights, areas and separation distances. The fields were calculated at various points on three distribution lines supposed to exist in front of the group of buildings, in its middle and behind it. Two different striking points were considered on the top of two chosen buildings. The simulations have shown a general field reduction due to the group of buildings, depending on their dimensions and heights, and on the position of the lightning striking point, but with not significant dependence on the separation distance between buildings. As expected, in some conditions polarity inversion of the vertical electric field can occur.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"287 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The effect of a group of buildings on the lightning electromagnetic fields\",\"authors\":\"M. S. Vieira, J. M. Janiszewski\",\"doi\":\"10.1109/SIPDA.2015.7339332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Among the various factors that influence the lightning electromagnetic fields, the presence of obstacles such as buildings has deserved some few studies. The paper presents the results related to the influence of a group of buildings on the vertical electric field, by a 3D FDTD code developed for a more complete study. Two rows of concrete buildings were considered, with different heights, areas and separation distances. The fields were calculated at various points on three distribution lines supposed to exist in front of the group of buildings, in its middle and behind it. Two different striking points were considered on the top of two chosen buildings. The simulations have shown a general field reduction due to the group of buildings, depending on their dimensions and heights, and on the position of the lightning striking point, but with not significant dependence on the separation distance between buildings. As expected, in some conditions polarity inversion of the vertical electric field can occur.\",\"PeriodicalId\":296478,\"journal\":{\"name\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"volume\":\"287 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2015.7339332\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在影响雷电电磁场的诸多因素中,建筑物等障碍物的存在值得较少的研究。本文介绍了一组建筑物对竖向电场影响的相关结果,并开发了三维时域有限差分程序,以进行更全面的研究。考虑两排混凝土建筑,具有不同的高度、面积和间隔距离。田地是在三条配电线上的不同点上计算出来的,这三条配电线上应该存在于建筑群的前面、中间和后面。在两个选定的建筑物的顶部考虑了两个不同的打击点。模拟结果表明,由于建筑物群的大小和高度以及雷击点的位置,总体上电场减小,但与建筑物之间的距离无关。正如预期的那样,在某些条件下,垂直电场的极性反转可能发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of a group of buildings on the lightning electromagnetic fields
Among the various factors that influence the lightning electromagnetic fields, the presence of obstacles such as buildings has deserved some few studies. The paper presents the results related to the influence of a group of buildings on the vertical electric field, by a 3D FDTD code developed for a more complete study. Two rows of concrete buildings were considered, with different heights, areas and separation distances. The fields were calculated at various points on three distribution lines supposed to exist in front of the group of buildings, in its middle and behind it. Two different striking points were considered on the top of two chosen buildings. The simulations have shown a general field reduction due to the group of buildings, depending on their dimensions and heights, and on the position of the lightning striking point, but with not significant dependence on the separation distance between buildings. As expected, in some conditions polarity inversion of the vertical electric field can occur.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信