{"title":"人体血糖光学测量近红外区代表性波长测定/研究","authors":"M. Engin, Ibrahim Akkaya, A. J. Pahnvar, Yavuz Öztürk, T. Begüm Çetintaş","doi":"10.1109/TIPTEKNO.2016.7863069","DOIUrl":null,"url":null,"abstract":"In this study, the phantom mediums which has different optical characteristic were made for detecting of glucose level, then the transmittance based measurements were done. It was studied between 900–2500 nm wavelength which includes higher absorption bands of glucose. An index parameter was improved and used a windowing based method for determining the glucose amount. The correlation was searched between the acquired index parameter and glucose concentrations, and a sensitive wavelength was found for glucose estimation. From the results, 1322–1338 nm were found meaningful for this purpose. In addition, 2144–2165 nm are also found alternative or supplemental wavelengths.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"171 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Representative wavelength determination/investigation in the near infrared region for optical measuring of the human blood glucose\",\"authors\":\"M. Engin, Ibrahim Akkaya, A. J. Pahnvar, Yavuz Öztürk, T. Begüm Çetintaş\",\"doi\":\"10.1109/TIPTEKNO.2016.7863069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, the phantom mediums which has different optical characteristic were made for detecting of glucose level, then the transmittance based measurements were done. It was studied between 900–2500 nm wavelength which includes higher absorption bands of glucose. An index parameter was improved and used a windowing based method for determining the glucose amount. The correlation was searched between the acquired index parameter and glucose concentrations, and a sensitive wavelength was found for glucose estimation. From the results, 1322–1338 nm were found meaningful for this purpose. In addition, 2144–2165 nm are also found alternative or supplemental wavelengths.\",\"PeriodicalId\":431660,\"journal\":{\"name\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"volume\":\"171 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIPTEKNO.2016.7863069\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO.2016.7863069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究制作了具有不同光学特性的幻像介质用于葡萄糖水平的检测,并进行了基于透过率的测量。在900 - 2500nm波长范围内进行了研究,其中葡萄糖的吸收波段较高。改进了指标参数,采用基于窗口的方法测定葡萄糖量。研究了所得指标参数与葡萄糖浓度的相关性,找到了葡萄糖浓度的敏感波长。从结果来看,1322-1338 nm对这个目的是有意义的。此外,还发现了2144-2165 nm的替代或补充波长。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Representative wavelength determination/investigation in the near infrared region for optical measuring of the human blood glucose
In this study, the phantom mediums which has different optical characteristic were made for detecting of glucose level, then the transmittance based measurements were done. It was studied between 900–2500 nm wavelength which includes higher absorption bands of glucose. An index parameter was improved and used a windowing based method for determining the glucose amount. The correlation was searched between the acquired index parameter and glucose concentrations, and a sensitive wavelength was found for glucose estimation. From the results, 1322–1338 nm were found meaningful for this purpose. In addition, 2144–2165 nm are also found alternative or supplemental wavelengths.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信