一种冠状动脉内OCT图像自动检测管腔的新方法

Hadi Soltanizadeh, Setareh Rezaee Oshterinan
{"title":"一种冠状动脉内OCT图像自动检测管腔的新方法","authors":"Hadi Soltanizadeh, Setareh Rezaee Oshterinan","doi":"10.1109/ICBME.2014.7043918","DOIUrl":null,"url":null,"abstract":"Intracoronary optical coherence tomography (OCT) is a catheter based medical imaging technique that provide high resolution imaging of coronary lumen structures. However these images affected by catheter and stents shadows during pullback procedure. In order to overcome this problem, we present a new approach to detect the lumen boundary automatically using fuzzy system. At the first, the OCT images are mapped into the normalized polar OCT (NPOCT) space, and then primal lumen boundary is estimated by image processing methods. Afterwards, lumen boundary is detected by a fuzzy system precisely. Finally the results are remapped into the OCT image space. The proposed approach is compared with manual lumen detection (MLD), and HD and AD distance results are obtained.","PeriodicalId":434822,"journal":{"name":"2014 21th Iranian Conference on Biomedical Engineering (ICBME)","volume":"447 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A new method for automatic lumen detection in intracoronary OCT images\",\"authors\":\"Hadi Soltanizadeh, Setareh Rezaee Oshterinan\",\"doi\":\"10.1109/ICBME.2014.7043918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Intracoronary optical coherence tomography (OCT) is a catheter based medical imaging technique that provide high resolution imaging of coronary lumen structures. However these images affected by catheter and stents shadows during pullback procedure. In order to overcome this problem, we present a new approach to detect the lumen boundary automatically using fuzzy system. At the first, the OCT images are mapped into the normalized polar OCT (NPOCT) space, and then primal lumen boundary is estimated by image processing methods. Afterwards, lumen boundary is detected by a fuzzy system precisely. Finally the results are remapped into the OCT image space. The proposed approach is compared with manual lumen detection (MLD), and HD and AD distance results are obtained.\",\"PeriodicalId\":434822,\"journal\":{\"name\":\"2014 21th Iranian Conference on Biomedical Engineering (ICBME)\",\"volume\":\"447 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 21th Iranian Conference on Biomedical Engineering (ICBME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBME.2014.7043918\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 21th Iranian Conference on Biomedical Engineering (ICBME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBME.2014.7043918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

冠状动脉内光学相干断层扫描(OCT)是一种基于导管的医学成像技术,可提供冠状动脉腔结构的高分辨率成像。然而,这些图像在回拉过程中受到导管和支架阴影的影响。为了克服这一问题,我们提出了一种利用模糊系统自动检测腔体边界的新方法。首先将OCT图像映射到归一化极化OCT (NPOCT)空间,然后通过图像处理方法估计原始腔体边界。然后用模糊系统精确地检测出腔体边界。最后将结果重新映射到OCT图像空间中。将该方法与人工流明检测(MLD)进行了比较,得到了HD和AD距离结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new method for automatic lumen detection in intracoronary OCT images
Intracoronary optical coherence tomography (OCT) is a catheter based medical imaging technique that provide high resolution imaging of coronary lumen structures. However these images affected by catheter and stents shadows during pullback procedure. In order to overcome this problem, we present a new approach to detect the lumen boundary automatically using fuzzy system. At the first, the OCT images are mapped into the normalized polar OCT (NPOCT) space, and then primal lumen boundary is estimated by image processing methods. Afterwards, lumen boundary is detected by a fuzzy system precisely. Finally the results are remapped into the OCT image space. The proposed approach is compared with manual lumen detection (MLD), and HD and AD distance results are obtained.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信