振动触觉时间总和:频率的影响。

Sensory processes Pub Date : 1976-12-01
B G Green
{"title":"振动触觉时间总和:频率的影响。","authors":"B G Green","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Temporal summation of vibrotactile stimuli was measured at four frequencies (25, 40, 80, and 160 Hz) using a large contactor. Stimulation at 160 Hz gave temporal summation comparable in amount to that reported in previous studies. Stimulation at 25, 40, and 80 Hz gave less summation. The presence of summation at low frequencies is unexpected in view of existing data obtained with small contactors' those data indicate that the afferent system primarily sensitive to low frequencies may not summate stimulus energy over time. The present data suggest either that the low-frequency afferents do summate energy over time or that, under some conditions, the perception of low-frequency signals presented through a large contactor may be mediated by more than one afferent system.</p>","PeriodicalId":76537,"journal":{"name":"Sensory processes","volume":"1 2","pages":"138-49"},"PeriodicalIF":0.0000,"publicationDate":"1976-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Vibrotactile temporal summation: effect of frequency.\",\"authors\":\"B G Green\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Temporal summation of vibrotactile stimuli was measured at four frequencies (25, 40, 80, and 160 Hz) using a large contactor. Stimulation at 160 Hz gave temporal summation comparable in amount to that reported in previous studies. Stimulation at 25, 40, and 80 Hz gave less summation. The presence of summation at low frequencies is unexpected in view of existing data obtained with small contactors' those data indicate that the afferent system primarily sensitive to low frequencies may not summate stimulus energy over time. The present data suggest either that the low-frequency afferents do summate energy over time or that, under some conditions, the perception of low-frequency signals presented through a large contactor may be mediated by more than one afferent system.</p>\",\"PeriodicalId\":76537,\"journal\":{\"name\":\"Sensory processes\",\"volume\":\"1 2\",\"pages\":\"138-49\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1976-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensory processes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensory processes","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用大型接触器在四个频率(25、40、80和160 Hz)下测量振动触觉刺激的时间总和。160hz的刺激产生的时间总和与先前研究报告的数量相当。25、40和80赫兹的刺激产生的总和较小。考虑到用小接触器获得的现有数据,低频求和的存在是出乎意料的。这些数据表明,主要对低频敏感的传入系统可能不会随着时间的推移对刺激能量求和。目前的数据表明,要么低频传入确实随时间累积能量,要么在某些条件下,通过大型接触器呈现的低频信号的感知可能由多个传入系统介导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Vibrotactile temporal summation: effect of frequency.

Temporal summation of vibrotactile stimuli was measured at four frequencies (25, 40, 80, and 160 Hz) using a large contactor. Stimulation at 160 Hz gave temporal summation comparable in amount to that reported in previous studies. Stimulation at 25, 40, and 80 Hz gave less summation. The presence of summation at low frequencies is unexpected in view of existing data obtained with small contactors' those data indicate that the afferent system primarily sensitive to low frequencies may not summate stimulus energy over time. The present data suggest either that the low-frequency afferents do summate energy over time or that, under some conditions, the perception of low-frequency signals presented through a large contactor may be mediated by more than one afferent system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信