安装在400千伏古蒂纳斯-布拉索夫0 /h线路(94-100塔之间)山区的带电避雷器

G. Florea, D. Marginean, M. Oltean, C. Chiriac, I. Rodean, A. Mazilu, C. Oprea
{"title":"安装在400千伏古蒂纳斯-布拉索夫0 /h线路(94-100塔之间)山区的带电避雷器","authors":"G. Florea, D. Marginean, M. Oltean, C. Chiriac, I. Rodean, A. Mazilu, C. Oprea","doi":"10.1109/ICOLIM.2014.6934358","DOIUrl":null,"url":null,"abstract":"The line section of the existing 400 kV Gutinas- Brasov is located in a mountain area with rocky soil. Because of the thick ice covering the conductors during the winter times causing the shieldwire breaking the shieldwires had to be dismantled long time ago. Without the shielding screen of the shieldwires the line section was left open to be struck by lightning. To reduce the lightning impact the solution of arrester installing was selected. Two types of towers are to be analyzed to may find the best solutions to locate the arresters. Both the electrical and mechanical aspects were considered. The 400kV OHL Gutinas- Brasov being an important line it is very difficult to be deenergised. That was an important reason for which live working technologies were developed and applied for mounting the arresters.","PeriodicalId":238060,"journal":{"name":"2014 11th International Conference on Live Maintenance (ICOLIM)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Live - line surge arrester installing on a mountain section of the 400 kV Gutinas- Brasov o/h line (between towers 94–100)\",\"authors\":\"G. Florea, D. Marginean, M. Oltean, C. Chiriac, I. Rodean, A. Mazilu, C. Oprea\",\"doi\":\"10.1109/ICOLIM.2014.6934358\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The line section of the existing 400 kV Gutinas- Brasov is located in a mountain area with rocky soil. Because of the thick ice covering the conductors during the winter times causing the shieldwire breaking the shieldwires had to be dismantled long time ago. Without the shielding screen of the shieldwires the line section was left open to be struck by lightning. To reduce the lightning impact the solution of arrester installing was selected. Two types of towers are to be analyzed to may find the best solutions to locate the arresters. Both the electrical and mechanical aspects were considered. The 400kV OHL Gutinas- Brasov being an important line it is very difficult to be deenergised. That was an important reason for which live working technologies were developed and applied for mounting the arresters.\",\"PeriodicalId\":238060,\"journal\":{\"name\":\"2014 11th International Conference on Live Maintenance (ICOLIM)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 11th International Conference on Live Maintenance (ICOLIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICOLIM.2014.6934358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 11th International Conference on Live Maintenance (ICOLIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOLIM.2014.6934358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

现有的400千伏古提纳斯-布拉索夫线路部分位于岩石土壤的山区。由于冬季导体上覆盖着厚厚的冰,导致屏蔽线断裂,所以屏蔽线在很久以前就必须拆除。如果没有屏蔽线的屏蔽屏,线路部分就会被闪电击中。为减少雷电冲击,选择了安装避雷器的解决方案。将对两种类型的塔进行分析,以找到定位避雷器的最佳解决方案。电气和机械方面都考虑过。400kV古蒂纳斯-布拉索夫线路是一条重要线路,很难断电。这是开发和应用现场工作技术安装避雷器的一个重要原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Live - line surge arrester installing on a mountain section of the 400 kV Gutinas- Brasov o/h line (between towers 94–100)
The line section of the existing 400 kV Gutinas- Brasov is located in a mountain area with rocky soil. Because of the thick ice covering the conductors during the winter times causing the shieldwire breaking the shieldwires had to be dismantled long time ago. Without the shielding screen of the shieldwires the line section was left open to be struck by lightning. To reduce the lightning impact the solution of arrester installing was selected. Two types of towers are to be analyzed to may find the best solutions to locate the arresters. Both the electrical and mechanical aspects were considered. The 400kV OHL Gutinas- Brasov being an important line it is very difficult to be deenergised. That was an important reason for which live working technologies were developed and applied for mounting the arresters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信