{"title":"基于dsp的矩阵变换器在各种异常条件下的工作,具有实用性","authors":"V. Kumar, R. Joshi","doi":"10.1109/PEDES.2006.344394","DOIUrl":null,"url":null,"abstract":"The matrix converter connects the three phase power supply with the three phase load directly through a switching matrix composed of four-quadrant switches. The operation of matrix converter with unbalanced power supply has been analyzed. For this, a 230 V, 250 VA three phase to three phase matrix converter prototype is implemented using DSP based controller and tests have been carried out to evaluate and improve the stability of system under typical abnormal conditions. Digital storage oscilloscope & power quality analyzer are used for experimental observations.","PeriodicalId":262597,"journal":{"name":"2006 International Conference on Power Electronic, Drives and Energy Systems","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"DSP-Based Matrix Converter Operation Under Various Abnormal Conditions with Practicality\",\"authors\":\"V. Kumar, R. Joshi\",\"doi\":\"10.1109/PEDES.2006.344394\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The matrix converter connects the three phase power supply with the three phase load directly through a switching matrix composed of four-quadrant switches. The operation of matrix converter with unbalanced power supply has been analyzed. For this, a 230 V, 250 VA three phase to three phase matrix converter prototype is implemented using DSP based controller and tests have been carried out to evaluate and improve the stability of system under typical abnormal conditions. Digital storage oscilloscope & power quality analyzer are used for experimental observations.\",\"PeriodicalId\":262597,\"journal\":{\"name\":\"2006 International Conference on Power Electronic, Drives and Energy Systems\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 International Conference on Power Electronic, Drives and Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDES.2006.344394\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Power Electronic, Drives and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDES.2006.344394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
DSP-Based Matrix Converter Operation Under Various Abnormal Conditions with Practicality
The matrix converter connects the three phase power supply with the three phase load directly through a switching matrix composed of four-quadrant switches. The operation of matrix converter with unbalanced power supply has been analyzed. For this, a 230 V, 250 VA three phase to three phase matrix converter prototype is implemented using DSP based controller and tests have been carried out to evaluate and improve the stability of system under typical abnormal conditions. Digital storage oscilloscope & power quality analyzer are used for experimental observations.