D. Bellan
{"title":"三相电力系统负荷不对称引起的电压不平衡发射的近似电路表示","authors":"D. Bellan","doi":"10.1109/GEMCCON.2018.8628545","DOIUrl":null,"url":null,"abstract":"This work investigates from a circuit viewpoint the phenomenon of voltage unbalance emission due to load asymmetry in three-phase power systems. Voltage unbalance emission occurs whenever a power system shows a lack of structural symmetry between the three phases. In such a case, in fact, the transformation methods, such as the symmetrical component transformation, provide coupled modal circuits. As a result, in a practical three-phase three-wire power system, the positive-sequence circuit injects current into the negative-sequence circuit and therefore the load voltage shows a negative-sequence component due to modal circuits interaction. Since in many cases of practical interest the asymmetry level in a three-phase load can be regarded as a small perturbation with respect to the ideal symmetrical condition, in this paper a weak-coupling approach between sequence circuits is proposed. More specifically, load asymmetry is investigated, and analytical conditions for circuit weak-coupling are derived. In this case an approximate equivalent circuit for the estimation of voltage unbalance emission is derived. Analytical results are validated by means of numerical simulation of a radial power system with asymmetrical three-phase load.","PeriodicalId":394870,"journal":{"name":"2018 IEEE 4th Global Electromagnetic Compatibility Conference (GEMCCON)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Approximate Circuit Representation of Voltage Unbalance Emission Due to Load Asymmetry in Three-Phase Power Systems\",\"authors\":\"D. Bellan\",\"doi\":\"10.1109/GEMCCON.2018.8628545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work investigates from a circuit viewpoint the phenomenon of voltage unbalance emission due to load asymmetry in three-phase power systems. Voltage unbalance emission occurs whenever a power system shows a lack of structural symmetry between the three phases. In such a case, in fact, the transformation methods, such as the symmetrical component transformation, provide coupled modal circuits. As a result, in a practical three-phase three-wire power system, the positive-sequence circuit injects current into the negative-sequence circuit and therefore the load voltage shows a negative-sequence component due to modal circuits interaction. Since in many cases of practical interest the asymmetry level in a three-phase load can be regarded as a small perturbation with respect to the ideal symmetrical condition, in this paper a weak-coupling approach between sequence circuits is proposed. More specifically, load asymmetry is investigated, and analytical conditions for circuit weak-coupling are derived. In this case an approximate equivalent circuit for the estimation of voltage unbalance emission is derived. Analytical results are validated by means of numerical simulation of a radial power system with asymmetrical three-phase load.\",\"PeriodicalId\":394870,\"journal\":{\"name\":\"2018 IEEE 4th Global Electromagnetic Compatibility Conference (GEMCCON)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 4th Global Electromagnetic Compatibility Conference (GEMCCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GEMCCON.2018.8628545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 4th Global Electromagnetic Compatibility Conference (GEMCCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GEMCCON.2018.8628545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文从电路的角度研究了三相电力系统中由于负荷不对称引起的电压不平衡发射现象。当电力系统三相结构不对称时,就会产生电压不平衡发射。在这种情况下,实际上,变换方法,如对称分量变换,提供耦合模态电路。因此,在实际的三相三线制电力系统中,正序电路向负序电路注入电流,因此负载电压由于模态电路相互作用而呈现负序分量。由于在许多实际情况下,三相负载中的不对称水平可以看作是相对于理想对称条件的小扰动,因此本文提出了序列电路之间的弱耦合方法。更具体地说,研究了负载不对称性,并推导了电路弱耦合的解析条件。在这种情况下,导出了估计电压不平衡发射的近似等效电路。通过三相负荷不对称的径向电力系统的数值模拟,验证了分析结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Approximate Circuit Representation of Voltage Unbalance Emission Due to Load Asymmetry in Three-Phase Power Systems
This work investigates from a circuit viewpoint the phenomenon of voltage unbalance emission due to load asymmetry in three-phase power systems. Voltage unbalance emission occurs whenever a power system shows a lack of structural symmetry between the three phases. In such a case, in fact, the transformation methods, such as the symmetrical component transformation, provide coupled modal circuits. As a result, in a practical three-phase three-wire power system, the positive-sequence circuit injects current into the negative-sequence circuit and therefore the load voltage shows a negative-sequence component due to modal circuits interaction. Since in many cases of practical interest the asymmetry level in a three-phase load can be regarded as a small perturbation with respect to the ideal symmetrical condition, in this paper a weak-coupling approach between sequence circuits is proposed. More specifically, load asymmetry is investigated, and analytical conditions for circuit weak-coupling are derived. In this case an approximate equivalent circuit for the estimation of voltage unbalance emission is derived. Analytical results are validated by means of numerical simulation of a radial power system with asymmetrical three-phase load.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信