假设多重母线中断的风险评估

R. Bulbul, C. Ten, A. Ginter
{"title":"假设多重母线中断的风险评估","authors":"R. Bulbul, C. Ten, A. Ginter","doi":"10.1109/PESGM.2014.6939782","DOIUrl":null,"url":null,"abstract":"Online N - 1 or higher order contingencies presented at the control center console are enforced to ensure that the system can withstand a sudden disturbance under abnormal operating conditions. As the communication has evolved toward IP-based platform that further integrates with the physical facilities of substation protection, a potential cyberattack upon certain protection schemes can weaken the system operating conditions. Bus differential relays are one of the protection schemes that can de-energize and isolate partial/entire substation from the system due to the large number of components connected to it. The reverse pyramid model (RPM) is proposed in this work to systematically enumerate the combinations of hypothesized electrical disconnection protected by busbar differential relays in a substation. Two metrics are introduced: (1) bottleneck combination list and (2) risk index for individual busbars. These indices are provided to help dispatchers in the control centers with systems security readiness and decision making.","PeriodicalId":149134,"journal":{"name":"2014 IEEE PES General Meeting | Conference & Exposition","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Risk evaluation for hypothesized multiple busbar outages\",\"authors\":\"R. Bulbul, C. Ten, A. Ginter\",\"doi\":\"10.1109/PESGM.2014.6939782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Online N - 1 or higher order contingencies presented at the control center console are enforced to ensure that the system can withstand a sudden disturbance under abnormal operating conditions. As the communication has evolved toward IP-based platform that further integrates with the physical facilities of substation protection, a potential cyberattack upon certain protection schemes can weaken the system operating conditions. Bus differential relays are one of the protection schemes that can de-energize and isolate partial/entire substation from the system due to the large number of components connected to it. The reverse pyramid model (RPM) is proposed in this work to systematically enumerate the combinations of hypothesized electrical disconnection protected by busbar differential relays in a substation. Two metrics are introduced: (1) bottleneck combination list and (2) risk index for individual busbars. These indices are provided to help dispatchers in the control centers with systems security readiness and decision making.\",\"PeriodicalId\":149134,\"journal\":{\"name\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2014.6939782\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES General Meeting | Conference & Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2014.6939782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在线N - 1或更高阶突发事件呈现在控制中心控制台被强制执行,以确保系统能够承受异常运行条件下的突然干扰。随着通信向基于ip的平台发展,并与变电站保护的物理设施进一步融合,某些保护方案受到潜在的网络攻击会削弱系统的运行条件。母线差动继电器是一种保护方案,它可以使部分/整个变电站从系统中断电和隔离,因为它连接了大量的组件。在这项工作中,提出了反金字塔模型(RPM)来系统地枚举变电站中由母线差动继电器保护的假设电气断开的组合。引入了两个指标:(1)瓶颈组合表和(2)单个母线风险指数。这些指标可以帮助控制中心的调度员进行系统安全准备和决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Risk evaluation for hypothesized multiple busbar outages
Online N - 1 or higher order contingencies presented at the control center console are enforced to ensure that the system can withstand a sudden disturbance under abnormal operating conditions. As the communication has evolved toward IP-based platform that further integrates with the physical facilities of substation protection, a potential cyberattack upon certain protection schemes can weaken the system operating conditions. Bus differential relays are one of the protection schemes that can de-energize and isolate partial/entire substation from the system due to the large number of components connected to it. The reverse pyramid model (RPM) is proposed in this work to systematically enumerate the combinations of hypothesized electrical disconnection protected by busbar differential relays in a substation. Two metrics are introduced: (1) bottleneck combination list and (2) risk index for individual busbars. These indices are provided to help dispatchers in the control centers with systems security readiness and decision making.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信