{"title":"假设多重母线中断的风险评估","authors":"R. Bulbul, C. Ten, A. Ginter","doi":"10.1109/PESGM.2014.6939782","DOIUrl":null,"url":null,"abstract":"Online N - 1 or higher order contingencies presented at the control center console are enforced to ensure that the system can withstand a sudden disturbance under abnormal operating conditions. As the communication has evolved toward IP-based platform that further integrates with the physical facilities of substation protection, a potential cyberattack upon certain protection schemes can weaken the system operating conditions. Bus differential relays are one of the protection schemes that can de-energize and isolate partial/entire substation from the system due to the large number of components connected to it. The reverse pyramid model (RPM) is proposed in this work to systematically enumerate the combinations of hypothesized electrical disconnection protected by busbar differential relays in a substation. Two metrics are introduced: (1) bottleneck combination list and (2) risk index for individual busbars. These indices are provided to help dispatchers in the control centers with systems security readiness and decision making.","PeriodicalId":149134,"journal":{"name":"2014 IEEE PES General Meeting | Conference & Exposition","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Risk evaluation for hypothesized multiple busbar outages\",\"authors\":\"R. Bulbul, C. Ten, A. Ginter\",\"doi\":\"10.1109/PESGM.2014.6939782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Online N - 1 or higher order contingencies presented at the control center console are enforced to ensure that the system can withstand a sudden disturbance under abnormal operating conditions. As the communication has evolved toward IP-based platform that further integrates with the physical facilities of substation protection, a potential cyberattack upon certain protection schemes can weaken the system operating conditions. Bus differential relays are one of the protection schemes that can de-energize and isolate partial/entire substation from the system due to the large number of components connected to it. The reverse pyramid model (RPM) is proposed in this work to systematically enumerate the combinations of hypothesized electrical disconnection protected by busbar differential relays in a substation. Two metrics are introduced: (1) bottleneck combination list and (2) risk index for individual busbars. These indices are provided to help dispatchers in the control centers with systems security readiness and decision making.\",\"PeriodicalId\":149134,\"journal\":{\"name\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2014.6939782\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES General Meeting | Conference & Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2014.6939782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Risk evaluation for hypothesized multiple busbar outages
Online N - 1 or higher order contingencies presented at the control center console are enforced to ensure that the system can withstand a sudden disturbance under abnormal operating conditions. As the communication has evolved toward IP-based platform that further integrates with the physical facilities of substation protection, a potential cyberattack upon certain protection schemes can weaken the system operating conditions. Bus differential relays are one of the protection schemes that can de-energize and isolate partial/entire substation from the system due to the large number of components connected to it. The reverse pyramid model (RPM) is proposed in this work to systematically enumerate the combinations of hypothesized electrical disconnection protected by busbar differential relays in a substation. Two metrics are introduced: (1) bottleneck combination list and (2) risk index for individual busbars. These indices are provided to help dispatchers in the control centers with systems security readiness and decision making.