{"title":"高压直流电晕的电磁特性","authors":"A. Akses, O. Kalenderli","doi":"10.1109/ICSMC2.2003.1428297","DOIUrl":null,"url":null,"abstract":"This study gives the evaluation of the high voltage dc corona. For this purpose, electromagnetic characteristics of the dc corona discharge are observed. Both the positive and the negative corona for dc voltages are taken into account. The main concern is the electromagnetic interference caused by the corona. The level of noise is evaluated by the tests performed in semi-anechoic chamber, with different electrodes","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"60 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Electromagnetic characteristics of high voltage dc corona\",\"authors\":\"A. Akses, O. Kalenderli\",\"doi\":\"10.1109/ICSMC2.2003.1428297\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study gives the evaluation of the high voltage dc corona. For this purpose, electromagnetic characteristics of the dc corona discharge are observed. Both the positive and the negative corona for dc voltages are taken into account. The main concern is the electromagnetic interference caused by the corona. The level of noise is evaluated by the tests performed in semi-anechoic chamber, with different electrodes\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"60 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428297\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Electromagnetic characteristics of high voltage dc corona
This study gives the evaluation of the high voltage dc corona. For this purpose, electromagnetic characteristics of the dc corona discharge are observed. Both the positive and the negative corona for dc voltages are taken into account. The main concern is the electromagnetic interference caused by the corona. The level of noise is evaluated by the tests performed in semi-anechoic chamber, with different electrodes