用于外科手术中体内测量的带有USB接口的荧光分光计的研制

D. Fabila, J. M. de la Rosa, S. Stolik, E. Moreno, T. Lopez, M. Álvarez, A. Arellano, G. De La Rosa, R. Mercado, J. Soto
{"title":"用于外科手术中体内测量的带有USB接口的荧光分光计的研制","authors":"D. Fabila, J. M. de la Rosa, S. Stolik, E. Moreno, T. Lopez, M. Álvarez, A. Arellano, G. De La Rosa, R. Mercado, J. Soto","doi":"10.1109/CASME.2010.5706669","DOIUrl":null,"url":null,"abstract":"In this paper we present the development of a portable spectrofluorometer with USB interface for in vivo measurements in biological tissue. The equipment consists of a mini-spectrometer HR4000CG-UV-NIR, with a working range from 200 to 1100 nm with a resolution of 0.5 nm FWHM. As the excitation source a light emitting diode at 365 nm, with maximum radiant power of 200 mW was used. A bifurcated fiber optic (R200-UV/VIS) with six 200 µm diameter irradiation fibers and one 200 µm collection fiber is used. The system is powered and controlled with a laptop, avoiding the use of an external power supply. A program to select the light source, to process and measure spectra in real time was developed using the graphic language G of LabVIEW 8.2. Also, in this issue are presented in vivo measurements of diffuse reflection and fluorescence of non-neoplastic and neoplastic cerebral tissue of patients affected with glioblastoma multiform tumors (GBM).","PeriodicalId":337009,"journal":{"name":"2010 2nd Circuits and Systems for Medical and Environmental Applications Workshop (CASME)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Development of a spectrofluorometer with USB interface for in vivo measurements in surgical procedures\",\"authors\":\"D. Fabila, J. M. de la Rosa, S. Stolik, E. Moreno, T. Lopez, M. Álvarez, A. Arellano, G. De La Rosa, R. Mercado, J. Soto\",\"doi\":\"10.1109/CASME.2010.5706669\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we present the development of a portable spectrofluorometer with USB interface for in vivo measurements in biological tissue. The equipment consists of a mini-spectrometer HR4000CG-UV-NIR, with a working range from 200 to 1100 nm with a resolution of 0.5 nm FWHM. As the excitation source a light emitting diode at 365 nm, with maximum radiant power of 200 mW was used. A bifurcated fiber optic (R200-UV/VIS) with six 200 µm diameter irradiation fibers and one 200 µm collection fiber is used. The system is powered and controlled with a laptop, avoiding the use of an external power supply. A program to select the light source, to process and measure spectra in real time was developed using the graphic language G of LabVIEW 8.2. Also, in this issue are presented in vivo measurements of diffuse reflection and fluorescence of non-neoplastic and neoplastic cerebral tissue of patients affected with glioblastoma multiform tumors (GBM).\",\"PeriodicalId\":337009,\"journal\":{\"name\":\"2010 2nd Circuits and Systems for Medical and Environmental Applications Workshop (CASME)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 2nd Circuits and Systems for Medical and Environmental Applications Workshop (CASME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CASME.2010.5706669\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 2nd Circuits and Systems for Medical and Environmental Applications Workshop (CASME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CASME.2010.5706669","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文介绍了一种便携式USB接口荧光光谱仪的研制,用于生物组织的体内测量。该设备由一台HR4000CG-UV-NIR微型光谱仪组成,工作范围为200 ~ 1100nm,分辨率为0.5 nm FWHM。采用波长为365 nm,最大辐射功率为200 mW的发光二极管作为激发源。采用分岔光纤(R200-UV/VIS), 6根直径200µm的辐照光纤和1根直径200µm的采集光纤。该系统由笔记本电脑供电和控制,避免使用外部电源。利用LabVIEW 8.2的图形语言G开发了一个实时选择光源、处理和测量光谱的程序。此外,本文还介绍了多形性胶质母细胞瘤(GBM)患者非肿瘤性和肿瘤性脑组织的漫反射和荧光的体内测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a spectrofluorometer with USB interface for in vivo measurements in surgical procedures
In this paper we present the development of a portable spectrofluorometer with USB interface for in vivo measurements in biological tissue. The equipment consists of a mini-spectrometer HR4000CG-UV-NIR, with a working range from 200 to 1100 nm with a resolution of 0.5 nm FWHM. As the excitation source a light emitting diode at 365 nm, with maximum radiant power of 200 mW was used. A bifurcated fiber optic (R200-UV/VIS) with six 200 µm diameter irradiation fibers and one 200 µm collection fiber is used. The system is powered and controlled with a laptop, avoiding the use of an external power supply. A program to select the light source, to process and measure spectra in real time was developed using the graphic language G of LabVIEW 8.2. Also, in this issue are presented in vivo measurements of diffuse reflection and fluorescence of non-neoplastic and neoplastic cerebral tissue of patients affected with glioblastoma multiform tumors (GBM).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信