Mihai Andrucã, M. Adam, A. Dragomir, D. Astanei, Liviu Andrucã
{"title":"浅谈SF6对中压断路器的监测","authors":"Mihai Andrucã, M. Adam, A. Dragomir, D. Astanei, Liviu Andrucã","doi":"10.1109/ICEPE.2018.8559888","DOIUrl":null,"url":null,"abstract":"Medium voltage circuit breakers are important components on the chain of production, transmission and distribution of the energy to the consumers. The circuit breaker importance is from its capacity to make and break the currents from normal rated parameters and from short circuit currents. Over time the circuit breakers are losing them properties to break the high currents because of ageing and other electrical and mechanical stresses. From this fact is necessary to monitoring some parameters of circuit breaker. The goal of circuit breakers monitoring is to know its condition for minimize the equipment failure risk and to prevent undesirable interruptions and their effects. The paper presents the importance of a medium voltage circuit breaker with SF_6 in the power system, a monitoring system which was interfacing with the circuit breaker, respectively the waveforms and values obtained from its.","PeriodicalId":343896,"journal":{"name":"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"About Monitoring of Medium Voltage Circuit Breakers with SF6\",\"authors\":\"Mihai Andrucã, M. Adam, A. Dragomir, D. Astanei, Liviu Andrucã\",\"doi\":\"10.1109/ICEPE.2018.8559888\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medium voltage circuit breakers are important components on the chain of production, transmission and distribution of the energy to the consumers. The circuit breaker importance is from its capacity to make and break the currents from normal rated parameters and from short circuit currents. Over time the circuit breakers are losing them properties to break the high currents because of ageing and other electrical and mechanical stresses. From this fact is necessary to monitoring some parameters of circuit breaker. The goal of circuit breakers monitoring is to know its condition for minimize the equipment failure risk and to prevent undesirable interruptions and their effects. The paper presents the importance of a medium voltage circuit breaker with SF_6 in the power system, a monitoring system which was interfacing with the circuit breaker, respectively the waveforms and values obtained from its.\",\"PeriodicalId\":343896,\"journal\":{\"name\":\"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE.2018.8559888\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE.2018.8559888","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
About Monitoring of Medium Voltage Circuit Breakers with SF6
Medium voltage circuit breakers are important components on the chain of production, transmission and distribution of the energy to the consumers. The circuit breaker importance is from its capacity to make and break the currents from normal rated parameters and from short circuit currents. Over time the circuit breakers are losing them properties to break the high currents because of ageing and other electrical and mechanical stresses. From this fact is necessary to monitoring some parameters of circuit breaker. The goal of circuit breakers monitoring is to know its condition for minimize the equipment failure risk and to prevent undesirable interruptions and their effects. The paper presents the importance of a medium voltage circuit breaker with SF_6 in the power system, a monitoring system which was interfacing with the circuit breaker, respectively the waveforms and values obtained from its.