大电流真空电弧下的电极腐蚀

Z. Jiyan, Cheng Lichun
{"title":"大电流真空电弧下的电极腐蚀","authors":"Z. Jiyan, Cheng Lichun","doi":"10.1109/HOLM.1989.77947","DOIUrl":null,"url":null,"abstract":"Electrode erosion was measured under conditions of practical high current and axial magnetic field (AMF). Arc interruptions were made in a demountable vacuum chamber. Electrode erosion was assessed by weighting. It is shown that the rate of electrode erosion with AMF is 39.8 mu g/C and that without AMF it is 1.3 mg/C; the anode gains 15 mu g/C for diffused arcs.<<ETX>>","PeriodicalId":441734,"journal":{"name":"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Electrode erosion under high current vacuum arcs\",\"authors\":\"Z. Jiyan, Cheng Lichun\",\"doi\":\"10.1109/HOLM.1989.77947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrode erosion was measured under conditions of practical high current and axial magnetic field (AMF). Arc interruptions were made in a demountable vacuum chamber. Electrode erosion was assessed by weighting. It is shown that the rate of electrode erosion with AMF is 39.8 mu g/C and that without AMF it is 1.3 mg/C; the anode gains 15 mu g/C for diffused arcs.<<ETX>>\",\"PeriodicalId\":441734,\"journal\":{\"name\":\"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.1989.77947\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on Electrical Contacts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.1989.77947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在实际大电流和轴向磁场(AMF)条件下测量了电极的腐蚀。电弧中断是在可拆卸的真空室中进行的。电极侵蚀通过加权评估。结果表明,有AMF的电极腐蚀速率为39.8 mu g/C,无AMF的电极腐蚀速率为1.3 mg/C;扩散电弧的阳极增益为15 μ g/C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrode erosion under high current vacuum arcs
Electrode erosion was measured under conditions of practical high current and axial magnetic field (AMF). Arc interruptions were made in a demountable vacuum chamber. Electrode erosion was assessed by weighting. It is shown that the rate of electrode erosion with AMF is 39.8 mu g/C and that without AMF it is 1.3 mg/C; the anode gains 15 mu g/C for diffused arcs.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信