{"title":"非绝热锥形Hi-Bi光纤光纤环镜增强铁磁流磁光传感器的灵敏度","authors":"A. Layeghi, H. Latifi","doi":"10.1117/12.2265832","DOIUrl":null,"url":null,"abstract":"A magnetic field fiber optic sensor based on Nano-magnetic fluid and Hi-Bi non-adiabatic tapered optical fiber in fiber loop mirror (HB-TFLM) is proposed and theoretically explained. As compared to the reported magnetic fluid (MF) based sensors, the achieved sensitivity of the proposed sensor is 255 pm/mT, which is enhanced by 3.6 times of magnitude relative to in line non-adiabatic tapered optical fiber sensor, used only 0.1% of the volume concentration of MF nanoparticles. Detection limit of the HB-TFLM to external magnetic field in range from 0 to 21 mT and 22 to 50 mT was 7.8 μT and 39.2 μT, respectively.","PeriodicalId":198716,"journal":{"name":"2017 25th Optical Fiber Sensors Conference (OFS)","volume":"187 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Enhancement of the sensitivity of ferrofluidic magneto-optical fiber sensor by non-adiabatic tapered Hi-Bi fiber in fiber loop mirror\",\"authors\":\"A. Layeghi, H. Latifi\",\"doi\":\"10.1117/12.2265832\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A magnetic field fiber optic sensor based on Nano-magnetic fluid and Hi-Bi non-adiabatic tapered optical fiber in fiber loop mirror (HB-TFLM) is proposed and theoretically explained. As compared to the reported magnetic fluid (MF) based sensors, the achieved sensitivity of the proposed sensor is 255 pm/mT, which is enhanced by 3.6 times of magnitude relative to in line non-adiabatic tapered optical fiber sensor, used only 0.1% of the volume concentration of MF nanoparticles. Detection limit of the HB-TFLM to external magnetic field in range from 0 to 21 mT and 22 to 50 mT was 7.8 μT and 39.2 μT, respectively.\",\"PeriodicalId\":198716,\"journal\":{\"name\":\"2017 25th Optical Fiber Sensors Conference (OFS)\",\"volume\":\"187 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 25th Optical Fiber Sensors Conference (OFS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2265832\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 25th Optical Fiber Sensors Conference (OFS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2265832","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Enhancement of the sensitivity of ferrofluidic magneto-optical fiber sensor by non-adiabatic tapered Hi-Bi fiber in fiber loop mirror
A magnetic field fiber optic sensor based on Nano-magnetic fluid and Hi-Bi non-adiabatic tapered optical fiber in fiber loop mirror (HB-TFLM) is proposed and theoretically explained. As compared to the reported magnetic fluid (MF) based sensors, the achieved sensitivity of the proposed sensor is 255 pm/mT, which is enhanced by 3.6 times of magnitude relative to in line non-adiabatic tapered optical fiber sensor, used only 0.1% of the volume concentration of MF nanoparticles. Detection limit of the HB-TFLM to external magnetic field in range from 0 to 21 mT and 22 to 50 mT was 7.8 μT and 39.2 μT, respectively.