以智能手机为存储介质的无线心脏信号监测

Erika Loniza, Chairman Alfajar, Alya Izzaty Bika, Yuli Ermawati, W. Kartika
{"title":"以智能手机为存储介质的无线心脏信号监测","authors":"Erika Loniza, Chairman Alfajar, Alya Izzaty Bika, Yuli Ermawati, W. Kartika","doi":"10.1109/ice3is54102.2021.9649669","DOIUrl":null,"url":null,"abstract":"Early prevention of heart disease can be done by monitoring the condition of heart's health using an electrocardiograph (ECG). In order to make it easier for medical personnel to monitor heart signals, a media for storing results is needed when an examination is carried out. Storage media will be even more effective if it can be accessed remotely. The purpose of this study was to design a modified ECG to check the condition of the heart using a data logger system. The device is designed in simple and applicable which smartphone acts as the display in real-time and can store the readings. This problem is limited by the research device using one lead to monitor heart signals. This study uses AD8232 as a heart signal receiver from the body and Wemos Dl Mini as a link to WiFi to display data on a smartphone using a created application. The measurement and testing methods carried out are by comparing the heart rate (BPM) value with the Phantom ECG input read on a smartphone, comparing the readings of the human heart signal on smartphone and ECG, and testing the human BPM value on smartphone. The overall results of reading the BPM value in the design obtained the error value under 5%. Sending data from Wemos D1 Mini as a media hotspot programmed using Arduino IDE software works well. The results of the heart signal data that are read on the smartphone can be stored so that users can send or print them.","PeriodicalId":134945,"journal":{"name":"2021 1st International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wireless Heart Signal Monitoring with Smartphone as Storage Media\",\"authors\":\"Erika Loniza, Chairman Alfajar, Alya Izzaty Bika, Yuli Ermawati, W. Kartika\",\"doi\":\"10.1109/ice3is54102.2021.9649669\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Early prevention of heart disease can be done by monitoring the condition of heart's health using an electrocardiograph (ECG). In order to make it easier for medical personnel to monitor heart signals, a media for storing results is needed when an examination is carried out. Storage media will be even more effective if it can be accessed remotely. The purpose of this study was to design a modified ECG to check the condition of the heart using a data logger system. The device is designed in simple and applicable which smartphone acts as the display in real-time and can store the readings. This problem is limited by the research device using one lead to monitor heart signals. This study uses AD8232 as a heart signal receiver from the body and Wemos Dl Mini as a link to WiFi to display data on a smartphone using a created application. The measurement and testing methods carried out are by comparing the heart rate (BPM) value with the Phantom ECG input read on a smartphone, comparing the readings of the human heart signal on smartphone and ECG, and testing the human BPM value on smartphone. The overall results of reading the BPM value in the design obtained the error value under 5%. Sending data from Wemos D1 Mini as a media hotspot programmed using Arduino IDE software works well. The results of the heart signal data that are read on the smartphone can be stored so that users can send or print them.\",\"PeriodicalId\":134945,\"journal\":{\"name\":\"2021 1st International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 1st International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ice3is54102.2021.9649669\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 1st International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ice3is54102.2021.9649669","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

心脏疾病的早期预防可以通过使用心电图(ECG)监测心脏健康状况来完成。为了便于医务人员监测心脏信号,在进行检查时需要一种存储结果的介质。如果存储介质可以远程访问,那么它将更加有效。本研究的目的是设计一种改良心电图,使用数据记录仪系统检查心脏状况。该设备设计简单实用,由智能手机实时显示并存储读数。这个问题受限于研究设备使用一根导线来监测心脏信号。本研究使用AD8232作为来自身体的心脏信号接收器,并使用Wemos Dl Mini作为连接到WiFi的链接,使用创建的应用程序在智能手机上显示数据。进行的测量和测试方法是通过将心率(BPM)值与智能手机上读取的Phantom ECG输入值进行比较,将智能手机上的人类心脏信号与ECG的读数进行比较,以及在智能手机上测试人类BPM值。在设计中读取BPM值的总体结果得到误差值在5%以下。使用Arduino IDE软件编程的Wemos D1 Mini作为媒体热点发送数据效果良好。在智能手机上读取的心脏信号数据的结果可以存储,因此用户可以发送或打印它们。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wireless Heart Signal Monitoring with Smartphone as Storage Media
Early prevention of heart disease can be done by monitoring the condition of heart's health using an electrocardiograph (ECG). In order to make it easier for medical personnel to monitor heart signals, a media for storing results is needed when an examination is carried out. Storage media will be even more effective if it can be accessed remotely. The purpose of this study was to design a modified ECG to check the condition of the heart using a data logger system. The device is designed in simple and applicable which smartphone acts as the display in real-time and can store the readings. This problem is limited by the research device using one lead to monitor heart signals. This study uses AD8232 as a heart signal receiver from the body and Wemos Dl Mini as a link to WiFi to display data on a smartphone using a created application. The measurement and testing methods carried out are by comparing the heart rate (BPM) value with the Phantom ECG input read on a smartphone, comparing the readings of the human heart signal on smartphone and ECG, and testing the human BPM value on smartphone. The overall results of reading the BPM value in the design obtained the error value under 5%. Sending data from Wemos D1 Mini as a media hotspot programmed using Arduino IDE software works well. The results of the heart signal data that are read on the smartphone can be stored so that users can send or print them.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信