M. Abgrall, S. Bize, B. Chupin, J. Guéna, P. Laurent, P. Rosenbusch, P. Uhrich, G. Rovera
{"title":"基于ne - syte原子喷泉的UTC(OP)性能","authors":"M. Abgrall, S. Bize, B. Chupin, J. Guéna, P. Laurent, P. Rosenbusch, P. Uhrich, G. Rovera","doi":"10.1109/CPEM.2014.6898563","DOIUrl":null,"url":null,"abstract":"This paper presents the new method implemented since October 2012 to realize UTC(OP) at LNE-SYRTE, in Observatoire de Paris (OP), France. This time scale is based on a H-Maser steered by the LNE-SYRTE atomic fountains. We describe the algorithm and we discuss the results obtained over almost 2 years of operation. Since the implementation of the new method, the departure of UTC(OP) from UTC remained well below 10 ns.","PeriodicalId":129873,"journal":{"name":"2014 European Frequency and Time Forum (EFTF)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Performances of UTC(OP) based on LNE-SYRTE atomic fountains\",\"authors\":\"M. Abgrall, S. Bize, B. Chupin, J. Guéna, P. Laurent, P. Rosenbusch, P. Uhrich, G. Rovera\",\"doi\":\"10.1109/CPEM.2014.6898563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the new method implemented since October 2012 to realize UTC(OP) at LNE-SYRTE, in Observatoire de Paris (OP), France. This time scale is based on a H-Maser steered by the LNE-SYRTE atomic fountains. We describe the algorithm and we discuss the results obtained over almost 2 years of operation. Since the implementation of the new method, the departure of UTC(OP) from UTC remained well below 10 ns.\",\"PeriodicalId\":129873,\"journal\":{\"name\":\"2014 European Frequency and Time Forum (EFTF)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 European Frequency and Time Forum (EFTF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2014.6898563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 European Frequency and Time Forum (EFTF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performances of UTC(OP) based on LNE-SYRTE atomic fountains
This paper presents the new method implemented since October 2012 to realize UTC(OP) at LNE-SYRTE, in Observatoire de Paris (OP), France. This time scale is based on a H-Maser steered by the LNE-SYRTE atomic fountains. We describe the algorithm and we discuss the results obtained over almost 2 years of operation. Since the implementation of the new method, the departure of UTC(OP) from UTC remained well below 10 ns.