基于ne - syte原子喷泉的UTC(OP)性能

M. Abgrall, S. Bize, B. Chupin, J. Guéna, P. Laurent, P. Rosenbusch, P. Uhrich, G. Rovera
{"title":"基于ne - syte原子喷泉的UTC(OP)性能","authors":"M. Abgrall, S. Bize, B. Chupin, J. Guéna, P. Laurent, P. Rosenbusch, P. Uhrich, G. Rovera","doi":"10.1109/CPEM.2014.6898563","DOIUrl":null,"url":null,"abstract":"This paper presents the new method implemented since October 2012 to realize UTC(OP) at LNE-SYRTE, in Observatoire de Paris (OP), France. This time scale is based on a H-Maser steered by the LNE-SYRTE atomic fountains. We describe the algorithm and we discuss the results obtained over almost 2 years of operation. Since the implementation of the new method, the departure of UTC(OP) from UTC remained well below 10 ns.","PeriodicalId":129873,"journal":{"name":"2014 European Frequency and Time Forum (EFTF)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Performances of UTC(OP) based on LNE-SYRTE atomic fountains\",\"authors\":\"M. Abgrall, S. Bize, B. Chupin, J. Guéna, P. Laurent, P. Rosenbusch, P. Uhrich, G. Rovera\",\"doi\":\"10.1109/CPEM.2014.6898563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the new method implemented since October 2012 to realize UTC(OP) at LNE-SYRTE, in Observatoire de Paris (OP), France. This time scale is based on a H-Maser steered by the LNE-SYRTE atomic fountains. We describe the algorithm and we discuss the results obtained over almost 2 years of operation. Since the implementation of the new method, the departure of UTC(OP) from UTC remained well below 10 ns.\",\"PeriodicalId\":129873,\"journal\":{\"name\":\"2014 European Frequency and Time Forum (EFTF)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 European Frequency and Time Forum (EFTF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2014.6898563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 European Frequency and Time Forum (EFTF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了自2012年10月以来在法国巴黎天文台(OP)的ne - syte上实现UTC(OP)的新方法。这个时间尺度是基于由ne - syte原子喷泉控制的h -脉泽。我们描述了算法,并讨论了近2年的运行结果。自新方法实施以来,UTC(OP)与UTC的偏差一直低于10 ns。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performances of UTC(OP) based on LNE-SYRTE atomic fountains
This paper presents the new method implemented since October 2012 to realize UTC(OP) at LNE-SYRTE, in Observatoire de Paris (OP), France. This time scale is based on a H-Maser steered by the LNE-SYRTE atomic fountains. We describe the algorithm and we discuss the results obtained over almost 2 years of operation. Since the implementation of the new method, the departure of UTC(OP) from UTC remained well below 10 ns.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信