{"title":"100ghz全光时钟恢复与法布里-珀罗腔和半导体光放大器","authors":"L. Huo, Dong Wang, Qiang Wang, C. Lou","doi":"10.1364/ACPC.2012.AS2G.5","DOIUrl":null,"url":null,"abstract":"We demonstrated 100-GHz clock recovery from 100-Gb/s RZ-OOK optical signal. Fabry-Perot cavity was used as primary clock recovery stage, SOA and optical filter was deployed to reduce the amplitude fluctuation from 46% to 12%.","PeriodicalId":118096,"journal":{"name":"2012 Asia Communications and Photonics Conference (ACP)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"100-GHz all-optical clock recovery with Fabry-Perot cavity and semiconductor optical amplifier\",\"authors\":\"L. Huo, Dong Wang, Qiang Wang, C. Lou\",\"doi\":\"10.1364/ACPC.2012.AS2G.5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We demonstrated 100-GHz clock recovery from 100-Gb/s RZ-OOK optical signal. Fabry-Perot cavity was used as primary clock recovery stage, SOA and optical filter was deployed to reduce the amplitude fluctuation from 46% to 12%.\",\"PeriodicalId\":118096,\"journal\":{\"name\":\"2012 Asia Communications and Photonics Conference (ACP)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Asia Communications and Photonics Conference (ACP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1364/ACPC.2012.AS2G.5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Asia Communications and Photonics Conference (ACP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/ACPC.2012.AS2G.5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
100-GHz all-optical clock recovery with Fabry-Perot cavity and semiconductor optical amplifier
We demonstrated 100-GHz clock recovery from 100-Gb/s RZ-OOK optical signal. Fabry-Perot cavity was used as primary clock recovery stage, SOA and optical filter was deployed to reduce the amplitude fluctuation from 46% to 12%.