省煤器替代能源在锅炉中的效率分析

Moh Muchlishiin, Dino Erivianto
{"title":"省煤器替代能源在锅炉中的效率分析","authors":"Moh Muchlishiin, Dino Erivianto","doi":"10.55927/fjst.v2i8.5802","DOIUrl":null,"url":null,"abstract":"Efficiency is one of the efforts in implementing energy conservation. Economizers are an alternative source of energy that can survive because of the potential for energy efficiency. Economizer equipment in producing electrical energy and steam produces less than 10-30% fuel needed for a conventional energy plant. The Economizer system that was assumed in this study, there was an increase in boiler efficiency with an Economizer system of 19%. As for the need for burning calories in the combustion chamber with an Economizer system of 46,868,200,68 kcal/hour compared to a system without an Economizer of 61.003.054,86 kcal/hour. Thus the fuel requirement will be less with an Economizer system of 7,735 kg/hour compared to a system without an Economizer of 10.069 kg/hour. So that the results obtained with the same ratio and type of fuel, there is a fuel efficiency of 2.334 kg/hour.","PeriodicalId":143857,"journal":{"name":"Formosa Journal of Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Efficiency Analysis using Economizer Alternative Energy in Boilers\",\"authors\":\"Moh Muchlishiin, Dino Erivianto\",\"doi\":\"10.55927/fjst.v2i8.5802\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Efficiency is one of the efforts in implementing energy conservation. Economizers are an alternative source of energy that can survive because of the potential for energy efficiency. Economizer equipment in producing electrical energy and steam produces less than 10-30% fuel needed for a conventional energy plant. The Economizer system that was assumed in this study, there was an increase in boiler efficiency with an Economizer system of 19%. As for the need for burning calories in the combustion chamber with an Economizer system of 46,868,200,68 kcal/hour compared to a system without an Economizer of 61.003.054,86 kcal/hour. Thus the fuel requirement will be less with an Economizer system of 7,735 kg/hour compared to a system without an Economizer of 10.069 kg/hour. So that the results obtained with the same ratio and type of fuel, there is a fuel efficiency of 2.334 kg/hour.\",\"PeriodicalId\":143857,\"journal\":{\"name\":\"Formosa Journal of Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Formosa Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55927/fjst.v2i8.5802\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Formosa Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55927/fjst.v2i8.5802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提高效率是实现节能的努力之一。节能器是一种可替代的能源,因为它具有提高能源效率的潜力。省煤器设备在生产电能和蒸汽时产生的燃料不足传统能源厂所需燃料的10-30%。在本研究中假设的省煤器系统中,省煤器系统使锅炉效率提高了19%。对于有省煤器系统的燃烧室需要燃烧的热量为46,868,200,68千卡/小时,而无省煤器系统的燃烧热量为61.003,054,86千卡/小时。因此,与没有省煤器的系统相比,使用省煤器系统的燃油需求将减少7,735 kg/小时,而不使用省煤器的系统则为10.069 kg/小时。由此得出,在相同比例和燃料类型下,燃油效率为2.334 kg/h。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Efficiency Analysis using Economizer Alternative Energy in Boilers
Efficiency is one of the efforts in implementing energy conservation. Economizers are an alternative source of energy that can survive because of the potential for energy efficiency. Economizer equipment in producing electrical energy and steam produces less than 10-30% fuel needed for a conventional energy plant. The Economizer system that was assumed in this study, there was an increase in boiler efficiency with an Economizer system of 19%. As for the need for burning calories in the combustion chamber with an Economizer system of 46,868,200,68 kcal/hour compared to a system without an Economizer of 61.003.054,86 kcal/hour. Thus the fuel requirement will be less with an Economizer system of 7,735 kg/hour compared to a system without an Economizer of 10.069 kg/hour. So that the results obtained with the same ratio and type of fuel, there is a fuel efficiency of 2.334 kg/hour.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信