一种基于单通道的远程深度睡眠监测系统,用于家庭失眠诊断

Sana Tmar-Ben Hamida, B. Ahmed
{"title":"一种基于单通道的远程深度睡眠监测系统,用于家庭失眠诊断","authors":"Sana Tmar-Ben Hamida, B. Ahmed","doi":"10.1109/NTMS.2015.7266469","DOIUrl":null,"url":null,"abstract":"An efficient insomnia diagnosis and treatment requires the analysis of sleep stages and patterns in the vital signals and clinical face-to-face consultations. The measured signals are collected from different locations on the head and the body and used to evaluate the sleep quality and quantity. Generally, these measurements require spending several days of monitoring at sleep centers. However, the first night effect may cause perturbations to the control subjects and contrary to insomnia subjects who may sleep better because of the change of the sleep environment. Therefore, there is a great interest in developing non-invasive ambulatory physiological insomnia monitoring devices for in-home use. It has been shown in previous studies that the sleep quality can be evaluated based on the quantity of length of deep sleep particularly the slow wave sleep (SWS) periods. The aim of this paper is to present a new method to evaluate the deep sleep epochs using a single electrooculogram channel and to collect remotely the subjective data through sleep diaries.","PeriodicalId":115020,"journal":{"name":"2015 7th International Conference on New Technologies, Mobility and Security (NTMS)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A remote deep sleep monitoring system based on a single channel for in-home insomnia diagnosis\",\"authors\":\"Sana Tmar-Ben Hamida, B. Ahmed\",\"doi\":\"10.1109/NTMS.2015.7266469\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An efficient insomnia diagnosis and treatment requires the analysis of sleep stages and patterns in the vital signals and clinical face-to-face consultations. The measured signals are collected from different locations on the head and the body and used to evaluate the sleep quality and quantity. Generally, these measurements require spending several days of monitoring at sleep centers. However, the first night effect may cause perturbations to the control subjects and contrary to insomnia subjects who may sleep better because of the change of the sleep environment. Therefore, there is a great interest in developing non-invasive ambulatory physiological insomnia monitoring devices for in-home use. It has been shown in previous studies that the sleep quality can be evaluated based on the quantity of length of deep sleep particularly the slow wave sleep (SWS) periods. The aim of this paper is to present a new method to evaluate the deep sleep epochs using a single electrooculogram channel and to collect remotely the subjective data through sleep diaries.\",\"PeriodicalId\":115020,\"journal\":{\"name\":\"2015 7th International Conference on New Technologies, Mobility and Security (NTMS)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 7th International Conference on New Technologies, Mobility and Security (NTMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NTMS.2015.7266469\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 7th International Conference on New Technologies, Mobility and Security (NTMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NTMS.2015.7266469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

一个有效的失眠诊断和治疗需要分析睡眠阶段和模式的生命信号和临床面对面咨询。测量信号从头部和身体的不同位置收集,用于评估睡眠质量和睡眠时间。一般来说,这些测量需要在睡眠中心进行数天的监测。然而,首夜效应可能会对对照组受试者造成扰动,与失眠受试者相反,失眠受试者可能会因为睡眠环境的改变而睡得更好。因此,有一个很大的兴趣在开发无创门诊生理失眠监测设备在家庭使用。以往的研究表明,睡眠质量可以根据深度睡眠的时间长短来评估,尤其是慢波睡眠(SWS)时期。本文的目的是提出一种利用单眼电图通道评估深度睡眠时期的新方法,并通过睡眠日记远程采集主观数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A remote deep sleep monitoring system based on a single channel for in-home insomnia diagnosis
An efficient insomnia diagnosis and treatment requires the analysis of sleep stages and patterns in the vital signals and clinical face-to-face consultations. The measured signals are collected from different locations on the head and the body and used to evaluate the sleep quality and quantity. Generally, these measurements require spending several days of monitoring at sleep centers. However, the first night effect may cause perturbations to the control subjects and contrary to insomnia subjects who may sleep better because of the change of the sleep environment. Therefore, there is a great interest in developing non-invasive ambulatory physiological insomnia monitoring devices for in-home use. It has been shown in previous studies that the sleep quality can be evaluated based on the quantity of length of deep sleep particularly the slow wave sleep (SWS) periods. The aim of this paper is to present a new method to evaluate the deep sleep epochs using a single electrooculogram channel and to collect remotely the subjective data through sleep diaries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信