{"title":"生物阻抗谱参数辨识新方法","authors":"C. V. Marin, D. Marin","doi":"10.1109/ECCSC.2008.4611673","DOIUrl":null,"url":null,"abstract":"This paper deals with Cole model parameter identification in bioimpedance spectroscopy. A new method for the selection of test frequencies is proposed. The evaluation of the sensitivity functions versus frequency for the unknown parameters is employed. The sensitivity magnitude is used as a criterion for the test frequency selection.","PeriodicalId":249205,"journal":{"name":"2008 4th European Conference on Circuits and Systems for Communications","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"New parameter identification method in Bioimpedance Spectroscopy\",\"authors\":\"C. V. Marin, D. Marin\",\"doi\":\"10.1109/ECCSC.2008.4611673\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with Cole model parameter identification in bioimpedance spectroscopy. A new method for the selection of test frequencies is proposed. The evaluation of the sensitivity functions versus frequency for the unknown parameters is employed. The sensitivity magnitude is used as a criterion for the test frequency selection.\",\"PeriodicalId\":249205,\"journal\":{\"name\":\"2008 4th European Conference on Circuits and Systems for Communications\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 4th European Conference on Circuits and Systems for Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCSC.2008.4611673\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 4th European Conference on Circuits and Systems for Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCSC.2008.4611673","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New parameter identification method in Bioimpedance Spectroscopy
This paper deals with Cole model parameter identification in bioimpedance spectroscopy. A new method for the selection of test frequencies is proposed. The evaluation of the sensitivity functions versus frequency for the unknown parameters is employed. The sensitivity magnitude is used as a criterion for the test frequency selection.