辅助检测心律失常的连续动态心电图仪的设计与制造

J. Gnecchi, Fabian Ortega Vargas, V. H. O. Peregrino, Daniel Lorias Espinoza
{"title":"辅助检测心律失常的连续动态心电图仪的设计与制造","authors":"J. Gnecchi, Fabian Ortega Vargas, V. H. O. Peregrino, Daniel Lorias Espinoza","doi":"10.1109/CERMA.2010.124","DOIUrl":null,"url":null,"abstract":"Amongst the factors that benefit preventive treatment of cardiac patients are early detection and correct identification of cardiac arrhythmia patterns. However, in the State of Michoacán, Mexico, cardiac patients are seldom monitored as part of routine diagnostic in public health institutions due to the lack of ECG monitoring equipment. This paper describes the design and construction of an Ambulatory Electrocardiogram (ECG) Recorder, the ECGITM04. The ECG-ITM04 resulted from an initiative between Morelia Institute of Technology and the Michoacán State Public Health Secretariat to produce biopotential instrumentation for use as part of routine diagnostic in public health clinics. The 3-wire ECG monitoring device complies with several specifications: low-power consumption (battery operated), on-line graphics display, 7-days continuous data logger, patient electrical safety, minimal signal processing operations to facilitate the identification of cardiac arrhythmia patterns and a JTAG programming port so that the device can be updated without changing the data acquisition hardware.","PeriodicalId":119218,"journal":{"name":"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference","volume":"198 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design and Construction of a Continuous Ambulatory Electrocardiogram Recorder, Auxiliary in the Detection of Cardiac Arrhythmias\",\"authors\":\"J. Gnecchi, Fabian Ortega Vargas, V. H. O. Peregrino, Daniel Lorias Espinoza\",\"doi\":\"10.1109/CERMA.2010.124\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Amongst the factors that benefit preventive treatment of cardiac patients are early detection and correct identification of cardiac arrhythmia patterns. However, in the State of Michoacán, Mexico, cardiac patients are seldom monitored as part of routine diagnostic in public health institutions due to the lack of ECG monitoring equipment. This paper describes the design and construction of an Ambulatory Electrocardiogram (ECG) Recorder, the ECGITM04. The ECG-ITM04 resulted from an initiative between Morelia Institute of Technology and the Michoacán State Public Health Secretariat to produce biopotential instrumentation for use as part of routine diagnostic in public health clinics. The 3-wire ECG monitoring device complies with several specifications: low-power consumption (battery operated), on-line graphics display, 7-days continuous data logger, patient electrical safety, minimal signal processing operations to facilitate the identification of cardiac arrhythmia patterns and a JTAG programming port so that the device can be updated without changing the data acquisition hardware.\",\"PeriodicalId\":119218,\"journal\":{\"name\":\"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference\",\"volume\":\"198 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CERMA.2010.124\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Electronics, Robotics and Automotive Mechanics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CERMA.2010.124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

早期发现和正确识别心律失常类型是对心脏病患者进行预防性治疗有益的因素之一。然而,在墨西哥Michoacán州,由于缺乏心电图监测设备,在公共卫生机构很少将心脏病患者作为常规诊断的一部分进行监测。本文介绍了动态心电图仪ECGITM04的设计和构造。心电图- itm04源于莫雷利亚理工学院与Michoacán国家公共卫生秘书处之间的一项倡议,旨在生产生物电位仪器,作为公共卫生诊所常规诊断的一部分。3线制心电监护设备符合以下几个规格:低功耗(电池供电),在线图形显示,7天连续数据记录器,患者电气安全,最小的信号处理操作,方便心律失常模式的识别,JTAG编程端口,使设备可以在不改变数据采集硬件的情况下进行更新。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and Construction of a Continuous Ambulatory Electrocardiogram Recorder, Auxiliary in the Detection of Cardiac Arrhythmias
Amongst the factors that benefit preventive treatment of cardiac patients are early detection and correct identification of cardiac arrhythmia patterns. However, in the State of Michoacán, Mexico, cardiac patients are seldom monitored as part of routine diagnostic in public health institutions due to the lack of ECG monitoring equipment. This paper describes the design and construction of an Ambulatory Electrocardiogram (ECG) Recorder, the ECGITM04. The ECG-ITM04 resulted from an initiative between Morelia Institute of Technology and the Michoacán State Public Health Secretariat to produce biopotential instrumentation for use as part of routine diagnostic in public health clinics. The 3-wire ECG monitoring device complies with several specifications: low-power consumption (battery operated), on-line graphics display, 7-days continuous data logger, patient electrical safety, minimal signal processing operations to facilitate the identification of cardiac arrhythmia patterns and a JTAG programming port so that the device can be updated without changing the data acquisition hardware.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信