{"title":"有机太阳能电池的回收性能","authors":"D. Naas, B. Larbi, Bessissa Lakhdar","doi":"10.1109/ICAEE47123.2019.9014758","DOIUrl":null,"url":null,"abstract":"In this paper, we have studied the degradation of organic solar cells (OSCs) in different way considering the recovery phenomenon. The carried out work is based on the application of outdoor test in the SDU laboratory (Sonderborg Denmark) by using the protocol ISOS-O-1. The test took 14 days, this duration is divided into two parts: first part 5 days where the samples were put in the roof for the degradation for 7 hours and we measure the electric parameters before putting them on the roof and in the glovebox. In the second part the samples were put in the glovebox for all the remaining days and different parameters have been measured two times per-day (morning-evening) the duration of the second part is 9 days.","PeriodicalId":197612,"journal":{"name":"2019 International Conference on Advanced Electrical Engineering (ICAEE)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of Organic Solar Cells with Recovery\",\"authors\":\"D. Naas, B. Larbi, Bessissa Lakhdar\",\"doi\":\"10.1109/ICAEE47123.2019.9014758\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we have studied the degradation of organic solar cells (OSCs) in different way considering the recovery phenomenon. The carried out work is based on the application of outdoor test in the SDU laboratory (Sonderborg Denmark) by using the protocol ISOS-O-1. The test took 14 days, this duration is divided into two parts: first part 5 days where the samples were put in the roof for the degradation for 7 hours and we measure the electric parameters before putting them on the roof and in the glovebox. In the second part the samples were put in the glovebox for all the remaining days and different parameters have been measured two times per-day (morning-evening) the duration of the second part is 9 days.\",\"PeriodicalId\":197612,\"journal\":{\"name\":\"2019 International Conference on Advanced Electrical Engineering (ICAEE)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Advanced Electrical Engineering (ICAEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAEE47123.2019.9014758\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Advanced Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE47123.2019.9014758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文从不同的角度研究了有机太阳能电池的降解,并考虑了回收现象。所开展的工作是基于在SDU实验室(丹麦森德堡)使用iso - o -1协议进行室外测试的应用。测试耗时14天,时间分为两部分:第一部分5天,将样品放在屋顶进行降解7小时,在将样品放在屋顶和手套箱中之前,我们测量了电气参数。在第二部分中,剩余的所有天将样品放入手套箱中,每天两次(早晚)测量不同的参数,第二部分的持续时间为9天。
In this paper, we have studied the degradation of organic solar cells (OSCs) in different way considering the recovery phenomenon. The carried out work is based on the application of outdoor test in the SDU laboratory (Sonderborg Denmark) by using the protocol ISOS-O-1. The test took 14 days, this duration is divided into two parts: first part 5 days where the samples were put in the roof for the degradation for 7 hours and we measure the electric parameters before putting them on the roof and in the glovebox. In the second part the samples were put in the glovebox for all the remaining days and different parameters have been measured two times per-day (morning-evening) the duration of the second part is 9 days.