{"title":"中性点箝位电压型PWM逆变器中性点电位变化分析","authors":"Satoshi Ogasawara, Hirofumi Akagi","doi":"10.1109/IAS.1993.299015","DOIUrl":null,"url":null,"abstract":"The authors present the analysis of the neutral-point potential variation of the neutral-point-clamped voltage source PWM (pulse-width-modulation) inverter (NPC-VSI) for AC motor drives and static VAr compensators (SVC). The potential variation is analyzed with the focus on the current flowing out of or into the neutral point of the DC link. The theoretical minimum capacity of the DC link capacitors is discussed for its application to both a vector-controlled induction motor system of 2.2 kW and a SVC system of 10 MVA, 6.6 kV, 60 Hz. It is shown that the proposed control scheme makes it possible to suppress the neutral-point potential variation within a few percent, so that the total capacity of the DC link capacitors in the NPC-VSI is almost the same as that in the conventional voltage source inverter.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"290","resultStr":"{\"title\":\"Analysis of variation of neutral point potential in neutral-point-clamped voltage source PWM inverters\",\"authors\":\"Satoshi Ogasawara, Hirofumi Akagi\",\"doi\":\"10.1109/IAS.1993.299015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors present the analysis of the neutral-point potential variation of the neutral-point-clamped voltage source PWM (pulse-width-modulation) inverter (NPC-VSI) for AC motor drives and static VAr compensators (SVC). The potential variation is analyzed with the focus on the current flowing out of or into the neutral point of the DC link. The theoretical minimum capacity of the DC link capacitors is discussed for its application to both a vector-controlled induction motor system of 2.2 kW and a SVC system of 10 MVA, 6.6 kV, 60 Hz. It is shown that the proposed control scheme makes it possible to suppress the neutral-point potential variation within a few percent, so that the total capacity of the DC link capacitors in the NPC-VSI is almost the same as that in the conventional voltage source inverter.<<ETX>>\",\"PeriodicalId\":345027,\"journal\":{\"name\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"290\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1993.299015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of variation of neutral point potential in neutral-point-clamped voltage source PWM inverters
The authors present the analysis of the neutral-point potential variation of the neutral-point-clamped voltage source PWM (pulse-width-modulation) inverter (NPC-VSI) for AC motor drives and static VAr compensators (SVC). The potential variation is analyzed with the focus on the current flowing out of or into the neutral point of the DC link. The theoretical minimum capacity of the DC link capacitors is discussed for its application to both a vector-controlled induction motor system of 2.2 kW and a SVC system of 10 MVA, 6.6 kV, 60 Hz. It is shown that the proposed control scheme makes it possible to suppress the neutral-point potential variation within a few percent, so that the total capacity of the DC link capacitors in the NPC-VSI is almost the same as that in the conventional voltage source inverter.<>