S. Krakauskaite, V. Petkus, R. Zakelis, L. Bartusis, R. Chomskis, A. Ragauskas
{"title":"创新的计算机无创颅内压测量技术及其临床验证","authors":"S. Krakauskaite, V. Petkus, R. Zakelis, L. Bartusis, R. Chomskis, A. Ragauskas","doi":"10.1109/CBMS.2014.40","DOIUrl":null,"url":null,"abstract":"An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extra cranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.","PeriodicalId":398710,"journal":{"name":"2014 IEEE 27th International Symposium on Computer-Based Medical Systems","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Innovative Computerized Non-invasive Intracranial Pressure Measurement Technology and Its Clinical Validation\",\"authors\":\"S. Krakauskaite, V. Petkus, R. Zakelis, L. Bartusis, R. Chomskis, A. Ragauskas\",\"doi\":\"10.1109/CBMS.2014.40\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extra cranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.\",\"PeriodicalId\":398710,\"journal\":{\"name\":\"2014 IEEE 27th International Symposium on Computer-Based Medical Systems\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE 27th International Symposium on Computer-Based Medical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMS.2014.40\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 27th International Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.2014.40","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Innovative Computerized Non-invasive Intracranial Pressure Measurement Technology and Its Clinical Validation
An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extra cranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.