创新的计算机无创颅内压测量技术及其临床验证

S. Krakauskaite, V. Petkus, R. Zakelis, L. Bartusis, R. Chomskis, A. Ragauskas
{"title":"创新的计算机无创颅内压测量技术及其临床验证","authors":"S. Krakauskaite, V. Petkus, R. Zakelis, L. Bartusis, R. Chomskis, A. Ragauskas","doi":"10.1109/CBMS.2014.40","DOIUrl":null,"url":null,"abstract":"An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extra cranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.","PeriodicalId":398710,"journal":{"name":"2014 IEEE 27th International Symposium on Computer-Based Medical Systems","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Innovative Computerized Non-invasive Intracranial Pressure Measurement Technology and Its Clinical Validation\",\"authors\":\"S. Krakauskaite, V. Petkus, R. Zakelis, L. Bartusis, R. Chomskis, A. Ragauskas\",\"doi\":\"10.1109/CBMS.2014.40\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extra cranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.\",\"PeriodicalId\":398710,\"journal\":{\"name\":\"2014 IEEE 27th International Symposium on Computer-Based Medical Systems\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE 27th International Symposium on Computer-Based Medical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMS.2014.40\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 27th International Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.2014.40","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

一种创新的无创绝对颅内压(aICP)测量方法已被多中心比较临床研究验证。该方法基于双深度经颅多普勒技术,采用眼动脉颅内和颅外段作为压力传感器。用眼动脉作为一对天然的尺度,比较眼内压内窥镜和眶外压内窥镜。在天平平衡情况下,aICP=aPe。双深度经颅多普勒装置用作压力平衡指示器。该方法是唯一一种不需要患者特异性校准的无创aICP测量方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Innovative Computerized Non-invasive Intracranial Pressure Measurement Technology and Its Clinical Validation
An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extra cranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信