{"title":"无源并联滤波器对海洋石油钻井平台电力系统谐波的抑制","authors":"S. Saha, R. Suryavanshi","doi":"10.1109/INDCON.2010.5712729","DOIUrl":null,"url":null,"abstract":"Offshore oil rigs use large dc drives, usually fed from a.c. utility services through ac/dc converters, thus distorting current and voltage waveforms. Passive filters have been very effective solution for the harmonic mitigation as well as reactive VAR compensation. However, improper choice of filter components may lead to severe voltage and current stress to power system components or even sometimes may further deteriorate the power quality. This paper describes an effective design procedure of passive filter to mitigate power system harmonics of a typical offshore oil rig.","PeriodicalId":109071,"journal":{"name":"2010 Annual IEEE India Conference (INDICON)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Power system harmonic mitigation of an offshore oil rig using passive shunt filter\",\"authors\":\"S. Saha, R. Suryavanshi\",\"doi\":\"10.1109/INDCON.2010.5712729\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Offshore oil rigs use large dc drives, usually fed from a.c. utility services through ac/dc converters, thus distorting current and voltage waveforms. Passive filters have been very effective solution for the harmonic mitigation as well as reactive VAR compensation. However, improper choice of filter components may lead to severe voltage and current stress to power system components or even sometimes may further deteriorate the power quality. This paper describes an effective design procedure of passive filter to mitigate power system harmonics of a typical offshore oil rig.\",\"PeriodicalId\":109071,\"journal\":{\"name\":\"2010 Annual IEEE India Conference (INDICON)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 Annual IEEE India Conference (INDICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INDCON.2010.5712729\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 Annual IEEE India Conference (INDICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDCON.2010.5712729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power system harmonic mitigation of an offshore oil rig using passive shunt filter
Offshore oil rigs use large dc drives, usually fed from a.c. utility services through ac/dc converters, thus distorting current and voltage waveforms. Passive filters have been very effective solution for the harmonic mitigation as well as reactive VAR compensation. However, improper choice of filter components may lead to severe voltage and current stress to power system components or even sometimes may further deteriorate the power quality. This paper describes an effective design procedure of passive filter to mitigate power system harmonics of a typical offshore oil rig.