{"title":"遗传算法在配电网电能质量监测仪优化配置中的应用","authors":"J. C. Cebrian, C. Almeida, N. Kagan","doi":"10.1109/ICHQP.2010.5625311","DOIUrl":null,"url":null,"abstract":"This paper presents a methodology which determines the optimal allocation of power quality monitors, in order to monitor the occurrence of voltage sags and swells in distribution networks. Initially, the methodology characterizes the system under analysis regarding the occurrence of voltage sag and swells. This characterization is performed through the simulation of several short-circuits at different points of the system being studied and taking in to consideration several conditions (fault impedance, fault type, etc.). For this purpose, a new method that defines the most relevant short-circuit conditions is proposed. After the system's characterization, the methodology makes use of Genetic Algorithms (GA) to define the minimum number of monitors required to monitor the whole system, and also the places where these monitors should be installed in the power network.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Genetic algorithms applied for the optimal allocation of power quality monitors in distribution networks\",\"authors\":\"J. C. Cebrian, C. Almeida, N. Kagan\",\"doi\":\"10.1109/ICHQP.2010.5625311\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a methodology which determines the optimal allocation of power quality monitors, in order to monitor the occurrence of voltage sags and swells in distribution networks. Initially, the methodology characterizes the system under analysis regarding the occurrence of voltage sag and swells. This characterization is performed through the simulation of several short-circuits at different points of the system being studied and taking in to consideration several conditions (fault impedance, fault type, etc.). For this purpose, a new method that defines the most relevant short-circuit conditions is proposed. After the system's characterization, the methodology makes use of Genetic Algorithms (GA) to define the minimum number of monitors required to monitor the whole system, and also the places where these monitors should be installed in the power network.\",\"PeriodicalId\":180078,\"journal\":{\"name\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2010.5625311\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

本文提出了一种确定电能质量监测仪最佳配置的方法,以监测配电网电压跌落和电压膨胀的发生。首先,该方法描述了被分析系统中电压跌落和膨胀的发生情况。这种表征是通过模拟系统不同点的几个短路来实现的,并考虑到几个条件(故障阻抗、故障类型等)。为此,提出了一种确定最相关短路条件的新方法。在对系统进行表征之后,该方法利用遗传算法(GA)来定义监控整个系统所需的最小监视器数量,以及这些监视器应安装在电网中的位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Genetic algorithms applied for the optimal allocation of power quality monitors in distribution networks
This paper presents a methodology which determines the optimal allocation of power quality monitors, in order to monitor the occurrence of voltage sags and swells in distribution networks. Initially, the methodology characterizes the system under analysis regarding the occurrence of voltage sag and swells. This characterization is performed through the simulation of several short-circuits at different points of the system being studied and taking in to consideration several conditions (fault impedance, fault type, etc.). For this purpose, a new method that defines the most relevant short-circuit conditions is proposed. After the system's characterization, the methodology makes use of Genetic Algorithms (GA) to define the minimum number of monitors required to monitor the whole system, and also the places where these monitors should be installed in the power network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信