用回电压法监测电力变压器绝缘状态

Gajanand Soni, S. Dutta, A. Baral
{"title":"用回电压法监测电力变压器绝缘状态","authors":"Gajanand Soni, S. Dutta, A. Baral","doi":"10.1109/catcon52335.2021.9670485","DOIUrl":null,"url":null,"abstract":"Due to ageing, insulation of the power transformers degrade. Ageing occurs mainly due to moisture content and oxygen in the oil-paper insulation of the power transformer. The ageing process causes an increase in the dissipation factor. To evaluate the service life of an in-situ transformer, condition monitoring of the insulation is essential. Researchers recently developed new techniques for condition assessment of power transformers insulation based on dielectric response measurement. However, the instruments used for those techniques are costly. In the present work, the return voltage measurement technique is used to estimate the high voltage insulation degradation; the data was obtained using a low-cost instrument. This paper reports the relationship between the initial rate of rising of RVM with variation in operational age and dielectric loss.","PeriodicalId":162130,"journal":{"name":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"172 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Condition Monitoring of Power Transformer Insulation by Return Voltage Measurement\",\"authors\":\"Gajanand Soni, S. Dutta, A. Baral\",\"doi\":\"10.1109/catcon52335.2021.9670485\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to ageing, insulation of the power transformers degrade. Ageing occurs mainly due to moisture content and oxygen in the oil-paper insulation of the power transformer. The ageing process causes an increase in the dissipation factor. To evaluate the service life of an in-situ transformer, condition monitoring of the insulation is essential. Researchers recently developed new techniques for condition assessment of power transformers insulation based on dielectric response measurement. However, the instruments used for those techniques are costly. In the present work, the return voltage measurement technique is used to estimate the high voltage insulation degradation; the data was obtained using a low-cost instrument. This paper reports the relationship between the initial rate of rising of RVM with variation in operational age and dielectric loss.\",\"PeriodicalId\":162130,\"journal\":{\"name\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"172 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/catcon52335.2021.9670485\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/catcon52335.2021.9670485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

由于老化,电力变压器的绝缘性能下降。发生老化的主要原因是电力变压器的油纸绝缘中含有水分和氧气。老化过程使耗散系数增大。为了评估原位变压器的使用寿命,绝缘状态监测是必不可少的。近年来,研究人员开发了基于介电响应测量的电力变压器绝缘状态评估新技术。然而,用于这些技术的仪器是昂贵的。在本工作中,采用返回电压测量技术来估计高压绝缘退化;数据是用一种低成本的仪器获得的。本文报道了RVM初始上升速率随运行年龄和介质损耗变化的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Condition Monitoring of Power Transformer Insulation by Return Voltage Measurement
Due to ageing, insulation of the power transformers degrade. Ageing occurs mainly due to moisture content and oxygen in the oil-paper insulation of the power transformer. The ageing process causes an increase in the dissipation factor. To evaluate the service life of an in-situ transformer, condition monitoring of the insulation is essential. Researchers recently developed new techniques for condition assessment of power transformers insulation based on dielectric response measurement. However, the instruments used for those techniques are costly. In the present work, the return voltage measurement technique is used to estimate the high voltage insulation degradation; the data was obtained using a low-cost instrument. This paper reports the relationship between the initial rate of rising of RVM with variation in operational age and dielectric loss.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信