一种新的谐波注入方法用于DVR系列注入变压器的过饱和抑制

Z. Yin, Lixia Zhou
{"title":"一种新的谐波注入方法用于DVR系列注入变压器的过饱和抑制","authors":"Z. Yin, Lixia Zhou","doi":"10.1109/IPEC.2005.206959","DOIUrl":null,"url":null,"abstract":"Voltage problems can be effectively solved by series compensators coupled with series injection transformers. However, the magnetic flux in iron core of series transformer may change in a large range depending on the close angle of injecting voltage, at the same time iron core easily get over saturated. Over saturation in transformer iron core leads to produce large field inrush current and distortion on compensating voltage wave, bring about hazard to operation of transformer and inverter, also increase the possibility of relay mishandling and finally decrease reliability of power supply. This paper analyzes the over saturation mechanism of series injection transformer and presents a novel harmonics injection control approach to suppress. The validity of proposed approach is verified by calculation and simulation","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A novel harmonics injecting approach on over saturation suppression of DVR series injection transformer\",\"authors\":\"Z. Yin, Lixia Zhou\",\"doi\":\"10.1109/IPEC.2005.206959\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage problems can be effectively solved by series compensators coupled with series injection transformers. However, the magnetic flux in iron core of series transformer may change in a large range depending on the close angle of injecting voltage, at the same time iron core easily get over saturated. Over saturation in transformer iron core leads to produce large field inrush current and distortion on compensating voltage wave, bring about hazard to operation of transformer and inverter, also increase the possibility of relay mishandling and finally decrease reliability of power supply. This paper analyzes the over saturation mechanism of series injection transformer and presents a novel harmonics injection control approach to suppress. The validity of proposed approach is verified by calculation and simulation\",\"PeriodicalId\":164802,\"journal\":{\"name\":\"2005 International Power Engineering Conference\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2005.206959\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.206959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

串联补偿器与串联注入变压器相结合可以有效地解决电压问题。然而,串联变压器铁心的磁通随注入电压闭合角度的不同而发生较大范围的变化,同时铁心容易发生过饱和。变压器铁心过饱和会产生较大的励磁涌流和补偿电压波畸变,给变压器和逆变器的运行带来危害,也增加了继电器误操作的可能性,最终降低了供电的可靠性。分析了串联注入变压器的过饱和机理,提出了一种新的谐波注入抑制方法。通过计算和仿真验证了该方法的有效性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel harmonics injecting approach on over saturation suppression of DVR series injection transformer
Voltage problems can be effectively solved by series compensators coupled with series injection transformers. However, the magnetic flux in iron core of series transformer may change in a large range depending on the close angle of injecting voltage, at the same time iron core easily get over saturated. Over saturation in transformer iron core leads to produce large field inrush current and distortion on compensating voltage wave, bring about hazard to operation of transformer and inverter, also increase the possibility of relay mishandling and finally decrease reliability of power supply. This paper analyzes the over saturation mechanism of series injection transformer and presents a novel harmonics injection control approach to suppress. The validity of proposed approach is verified by calculation and simulation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信