钛包覆PEEK植入物的初步评价

A. M. Rust-Dawicki, S. Cook
{"title":"钛包覆PEEK植入物的初步评价","authors":"A. M. Rust-Dawicki, S. Cook","doi":"10.1109/SBEC.1995.514436","DOIUrl":null,"url":null,"abstract":"A series of 40 titanium-coated and uncoated polyetheretherketone (PEEK) cylindrical implants were placed in unicortical sites in femurs of 4 mongrel dogs. The implants were evaluated mechanically and histologically at periods of 4 and 8 weeks. Interface attachment strength was calculated for each specimen, as well as measurements of bone contact, porosity, bone ingrowth, inflammatory response and mode of failure. Statistical analysis revealed the uncoated implants had significantly higher shear strength values at 4 weeks, but no significant difference from the coated implants at 8 weeks. There was no significant increase in bone contact between 4 and 8 weeks for either the coated or uncoated specimens. At both 4 and 8 weeks, the coated specimens had significantly higher percentages of bone contact.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"22 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Preliminary evaluation of titanium-coated PEEK implants\",\"authors\":\"A. M. Rust-Dawicki, S. Cook\",\"doi\":\"10.1109/SBEC.1995.514436\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A series of 40 titanium-coated and uncoated polyetheretherketone (PEEK) cylindrical implants were placed in unicortical sites in femurs of 4 mongrel dogs. The implants were evaluated mechanically and histologically at periods of 4 and 8 weeks. Interface attachment strength was calculated for each specimen, as well as measurements of bone contact, porosity, bone ingrowth, inflammatory response and mode of failure. Statistical analysis revealed the uncoated implants had significantly higher shear strength values at 4 weeks, but no significant difference from the coated implants at 8 weeks. There was no significant increase in bone contact between 4 and 8 weeks for either the coated or uncoated specimens. At both 4 and 8 weeks, the coated specimens had significantly higher percentages of bone contact.\",\"PeriodicalId\":332563,\"journal\":{\"name\":\"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference\",\"volume\":\"22 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SBEC.1995.514436\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBEC.1995.514436","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

将40个钛涂层和未涂层聚醚醚酮(PEEK)圆柱形植入物放置在4只杂种狗股骨的单皮质部位。在4周和8周期间对植入物进行机械和组织学评估。计算每个试样的界面附着强度,以及骨接触、孔隙度、骨向内生长、炎症反应和失效模式的测量。统计分析显示,未包覆种植体在第4周的抗剪强度值显著高于包覆种植体,但与包覆种植体在第8周的抗剪强度值无显著差异。在4到8周期间,无论是涂覆的还是未涂覆的标本,骨接触都没有显著增加。在第4周和第8周,包被标本的骨接触率显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preliminary evaluation of titanium-coated PEEK implants
A series of 40 titanium-coated and uncoated polyetheretherketone (PEEK) cylindrical implants were placed in unicortical sites in femurs of 4 mongrel dogs. The implants were evaluated mechanically and histologically at periods of 4 and 8 weeks. Interface attachment strength was calculated for each specimen, as well as measurements of bone contact, porosity, bone ingrowth, inflammatory response and mode of failure. Statistical analysis revealed the uncoated implants had significantly higher shear strength values at 4 weeks, but no significant difference from the coated implants at 8 weeks. There was no significant increase in bone contact between 4 and 8 weeks for either the coated or uncoated specimens. At both 4 and 8 weeks, the coated specimens had significantly higher percentages of bone contact.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信