降低ATE系统中HP 8566/68频谱分析仪过时相关风险的策略

Tom Hoppin
{"title":"降低ATE系统中HP 8566/68频谱分析仪过时相关风险的策略","authors":"Tom Hoppin","doi":"10.1109/AUTEST.2002.1047943","DOIUrl":null,"url":null,"abstract":"The Hewlett-Packard 8566 and 8568 were the first RF and microwave spectrum analyzers offering remote control and data transfer through the GPIB interface. These analyzers have been widely deployed in automated test equipment (ATE) systems and the majority of units produced since introduction 24 years ago are in active use. These instruments were discontinued five years ago, and Agilent Technologies will suspend support for them this year. This situation exposes ATE system managers to higher levels of risk than might be apparent. This paper outlines risk areas and presents a range of mitigation actions that affected managers might take. In describing those actions, a new option for HP 8566/68 programming code compatibility is introduced and discussed.","PeriodicalId":372875,"journal":{"name":"Proceedings, IEEE AUTOTESTCON","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Strategies for mitigating risk related to the obsolescence of HP 8566/68 spectrum analyzers in ATE systems\",\"authors\":\"Tom Hoppin\",\"doi\":\"10.1109/AUTEST.2002.1047943\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Hewlett-Packard 8566 and 8568 were the first RF and microwave spectrum analyzers offering remote control and data transfer through the GPIB interface. These analyzers have been widely deployed in automated test equipment (ATE) systems and the majority of units produced since introduction 24 years ago are in active use. These instruments were discontinued five years ago, and Agilent Technologies will suspend support for them this year. This situation exposes ATE system managers to higher levels of risk than might be apparent. This paper outlines risk areas and presents a range of mitigation actions that affected managers might take. In describing those actions, a new option for HP 8566/68 programming code compatibility is introduced and discussed.\",\"PeriodicalId\":372875,\"journal\":{\"name\":\"Proceedings, IEEE AUTOTESTCON\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings, IEEE AUTOTESTCON\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AUTEST.2002.1047943\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings, IEEE AUTOTESTCON","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUTEST.2002.1047943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

惠普8566和8568是第一款通过GPIB接口提供远程控制和数据传输的射频和微波频谱分析仪。这些分析仪已广泛部署在自动化测试设备(ATE)系统中,并且自24年前推出以来生产的大多数设备都在积极使用中。这些仪器在五年前就停产了,安捷伦科技公司今年将停止对它们的支持。这种情况使ATE系统管理人员面临比表面上更高的风险。本文概述了风险领域,并提出了受影响的管理人员可能采取的一系列缓解措施。在描述这些操作时,介绍并讨论了hp8566 /68编程代码兼容性的一个新选项。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Strategies for mitigating risk related to the obsolescence of HP 8566/68 spectrum analyzers in ATE systems
The Hewlett-Packard 8566 and 8568 were the first RF and microwave spectrum analyzers offering remote control and data transfer through the GPIB interface. These analyzers have been widely deployed in automated test equipment (ATE) systems and the majority of units produced since introduction 24 years ago are in active use. These instruments were discontinued five years ago, and Agilent Technologies will suspend support for them this year. This situation exposes ATE system managers to higher levels of risk than might be apparent. This paper outlines risk areas and presents a range of mitigation actions that affected managers might take. In describing those actions, a new option for HP 8566/68 programming code compatibility is introduced and discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信