MX-41/AR和Telephonics环耳听力耳机的噪声衰减特性。

G R Bienvenue, P L Michael
{"title":"MX-41/AR和Telephonics环耳听力耳机的噪声衰减特性。","authors":"G R Bienvenue,&nbsp;P L Michael","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Masking from background noise is often a serious problem when hearing levels are measured at or near the low reference threshold levels specified in the American National Standards Specifications for Audiometers, ANSI S3.6-1969. Since background noise limits for audiometric test rooms are inversely related to the noise reduction characteristics of the earphone/cushion assemblies, it is important that these units have significant and consistent attenuation properties. This paper reports the noise reduction characteristics measured for the conventional TDH-39 earphone mounted in the supra-aural MX-41/AR cushion and for the new TDH-50 Telephonics circumaural headset. The circumaural headset was found to produce an average of about 10 dB more noise attenuation than did a well-adjusted supra-aural device, and the circumaural headset provided much more consistent test-retest noise reduction characteristics. Theoretical aspects of headband force as well as the implications of attenuation measurements for test room recommendations are discussed.</p>","PeriodicalId":76026,"journal":{"name":"Journal of the American Audiology Society","volume":"4 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"1978-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Noise attenuation characteristics of the MX-41/AR and the Telephonics circumaural audiometric headsets.\",\"authors\":\"G R Bienvenue,&nbsp;P L Michael\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Masking from background noise is often a serious problem when hearing levels are measured at or near the low reference threshold levels specified in the American National Standards Specifications for Audiometers, ANSI S3.6-1969. Since background noise limits for audiometric test rooms are inversely related to the noise reduction characteristics of the earphone/cushion assemblies, it is important that these units have significant and consistent attenuation properties. This paper reports the noise reduction characteristics measured for the conventional TDH-39 earphone mounted in the supra-aural MX-41/AR cushion and for the new TDH-50 Telephonics circumaural headset. The circumaural headset was found to produce an average of about 10 dB more noise attenuation than did a well-adjusted supra-aural device, and the circumaural headset provided much more consistent test-retest noise reduction characteristics. Theoretical aspects of headband force as well as the implications of attenuation measurements for test room recommendations are discussed.</p>\",\"PeriodicalId\":76026,\"journal\":{\"name\":\"Journal of the American Audiology Society\",\"volume\":\"4 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Audiology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Audiology Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

当听力水平达到或接近美国国家标准规范(ANSI S3.6-1969)中规定的低参考阈值水平时,背景噪声的掩蔽通常是一个严重的问题。由于听力测试室的背景噪声限制与耳机/垫组件的降噪特性成反比,因此这些单元具有显著和一致的衰减特性非常重要。本文报道了安装在超听觉MX-41/AR垫中的传统TDH-39耳机和新型TDH-50 Telephonics环耳耳机的降噪特性。研究发现,与调节良好的超耳设备相比,环耳耳机的降噪效果平均高出约10 dB,并且环耳耳机提供了更一致的测试-再测试降噪特性。讨论了头带力的理论方面以及衰减测量对试验室建议的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Noise attenuation characteristics of the MX-41/AR and the Telephonics circumaural audiometric headsets.

Masking from background noise is often a serious problem when hearing levels are measured at or near the low reference threshold levels specified in the American National Standards Specifications for Audiometers, ANSI S3.6-1969. Since background noise limits for audiometric test rooms are inversely related to the noise reduction characteristics of the earphone/cushion assemblies, it is important that these units have significant and consistent attenuation properties. This paper reports the noise reduction characteristics measured for the conventional TDH-39 earphone mounted in the supra-aural MX-41/AR cushion and for the new TDH-50 Telephonics circumaural headset. The circumaural headset was found to produce an average of about 10 dB more noise attenuation than did a well-adjusted supra-aural device, and the circumaural headset provided much more consistent test-retest noise reduction characteristics. Theoretical aspects of headband force as well as the implications of attenuation measurements for test room recommendations are discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信