{"title":"男性直肠电位差测量方法的比较:直肠输注阿米洛利的效果。","authors":"F Mohamed, P McSorley, D J Warren","doi":"10.1042/cs0550231","DOIUrl":null,"url":null,"abstract":"<p><p>1. Two methods for measurement of rectal potential difference in man were compared. A saline-filled catheter technique gave more reproducible results and was better tolerated by patients than the solid probe technique. 2. Infusion of amiloride at a concentration of 4 x 10(-6) mol/l in saline produced a variable fall of potential difference in six normal subjects. Dose-response curves in two subjects showed that complete inhibition of rectal difference occurred at 4 x 10(-5) mol/l and 4 x 10(-6) mol/l respectively. 3. This finding provides additional evidence that rectal potential difference in man results from electrogenic ion transport across the mucosal epithelial cell.</p>","PeriodicalId":10356,"journal":{"name":"Clinical science and molecular medicine","volume":"55 3","pages":"231-4"},"PeriodicalIF":0.0000,"publicationDate":"1978-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1042/cs0550231","citationCount":"8","resultStr":"{\"title\":\"A comparison of methods for measurement of rectal potential difference in man: effects of rectal infusion of amiloride.\",\"authors\":\"F Mohamed, P McSorley, D J Warren\",\"doi\":\"10.1042/cs0550231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>1. Two methods for measurement of rectal potential difference in man were compared. A saline-filled catheter technique gave more reproducible results and was better tolerated by patients than the solid probe technique. 2. Infusion of amiloride at a concentration of 4 x 10(-6) mol/l in saline produced a variable fall of potential difference in six normal subjects. Dose-response curves in two subjects showed that complete inhibition of rectal difference occurred at 4 x 10(-5) mol/l and 4 x 10(-6) mol/l respectively. 3. This finding provides additional evidence that rectal potential difference in man results from electrogenic ion transport across the mucosal epithelial cell.</p>\",\"PeriodicalId\":10356,\"journal\":{\"name\":\"Clinical science and molecular medicine\",\"volume\":\"55 3\",\"pages\":\"231-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1042/cs0550231\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical science and molecular medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1042/cs0550231\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical science and molecular medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1042/cs0550231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparison of methods for measurement of rectal potential difference in man: effects of rectal infusion of amiloride.
1. Two methods for measurement of rectal potential difference in man were compared. A saline-filled catheter technique gave more reproducible results and was better tolerated by patients than the solid probe technique. 2. Infusion of amiloride at a concentration of 4 x 10(-6) mol/l in saline produced a variable fall of potential difference in six normal subjects. Dose-response curves in two subjects showed that complete inhibition of rectal difference occurred at 4 x 10(-5) mol/l and 4 x 10(-6) mol/l respectively. 3. This finding provides additional evidence that rectal potential difference in man results from electrogenic ion transport across the mucosal epithelial cell.