{"title":"天花免疫接种后vdrl玻片试验结果假阳性。","authors":"L C Seet, E H Sng, M Thomas","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A study is conducted on the incidence of false positive results in the serological test for syphilis in 300 military recruits following smallpox immunization. It is found that 3.7% of individuals developed false reactivity in the V D R L Slide test. The false reactivity appeared two to four weeks following immunization, and disappeared from two to eight weeks later. All reactive sera were negative in the FTA-ABS test.</p>","PeriodicalId":75568,"journal":{"name":"Asian journal of infectious diseases","volume":"3 3","pages":"137-8"},"PeriodicalIF":0.0000,"publicationDate":"1979-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"False positive results in V D R L slide test following smallpox immunization.\",\"authors\":\"L C Seet, E H Sng, M Thomas\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A study is conducted on the incidence of false positive results in the serological test for syphilis in 300 military recruits following smallpox immunization. It is found that 3.7% of individuals developed false reactivity in the V D R L Slide test. The false reactivity appeared two to four weeks following immunization, and disappeared from two to eight weeks later. All reactive sera were negative in the FTA-ABS test.</p>\",\"PeriodicalId\":75568,\"journal\":{\"name\":\"Asian journal of infectious diseases\",\"volume\":\"3 3\",\"pages\":\"137-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian journal of infectious diseases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian journal of infectious diseases","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
对300名新兵天花免疫后梅毒血清学检测假阳性的发生率进行了研究。结果发现,3.7%的个体在V D R L滑动测试中出现假反应。假反应在免疫后2 - 4周出现,2 - 8周后消失。所有反应性血清的FTA-ABS试验均为阴性。
False positive results in V D R L slide test following smallpox immunization.
A study is conducted on the incidence of false positive results in the serological test for syphilis in 300 military recruits following smallpox immunization. It is found that 3.7% of individuals developed false reactivity in the V D R L Slide test. The false reactivity appeared two to four weeks following immunization, and disappeared from two to eight weeks later. All reactive sera were negative in the FTA-ABS test.