{"title":"用于离网蓄电池逆变器的双向CLLC变换器前端","authors":"N. Radimov, R. Orr, T. Gachovska","doi":"10.1109/IHTC.2015.7238057","DOIUrl":null,"url":null,"abstract":"A bidirectional full-bridge CLLC resonant converter was proposed like front-end of off-grid battery inverter. The model of CLLC converter was derived. The effect of power MOSFET output capacitance on CLLC oscillation tank behavior was validated. The guideline for oscillation tank components and power MOSFETs choice was proposed. The 1kW peak-power off-grid battery inverter was built and tested.","PeriodicalId":178502,"journal":{"name":"2015 IEEE Canada International Humanitarian Technology Conference (IHTC2015)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Bi-directional CLLC converter front-end for off-grid battery inverters\",\"authors\":\"N. Radimov, R. Orr, T. Gachovska\",\"doi\":\"10.1109/IHTC.2015.7238057\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A bidirectional full-bridge CLLC resonant converter was proposed like front-end of off-grid battery inverter. The model of CLLC converter was derived. The effect of power MOSFET output capacitance on CLLC oscillation tank behavior was validated. The guideline for oscillation tank components and power MOSFETs choice was proposed. The 1kW peak-power off-grid battery inverter was built and tested.\",\"PeriodicalId\":178502,\"journal\":{\"name\":\"2015 IEEE Canada International Humanitarian Technology Conference (IHTC2015)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Canada International Humanitarian Technology Conference (IHTC2015)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IHTC.2015.7238057\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Canada International Humanitarian Technology Conference (IHTC2015)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IHTC.2015.7238057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Bi-directional CLLC converter front-end for off-grid battery inverters
A bidirectional full-bridge CLLC resonant converter was proposed like front-end of off-grid battery inverter. The model of CLLC converter was derived. The effect of power MOSFET output capacitance on CLLC oscillation tank behavior was validated. The guideline for oscillation tank components and power MOSFETs choice was proposed. The 1kW peak-power off-grid battery inverter was built and tested.