{"title":"防雷系统的电磁兼容效应:屋顶电网的屏蔽特性","authors":"S. Cristina, A. Orlandi","doi":"10.1109/ISEMC.1991.148188","DOIUrl":null,"url":null,"abstract":"A suitable set of parameters is used to evaluate the shielding performance of the roof-grid constituted by a mesh of conductors, electrically interconnected, laying on top of buildings with a large-area roof. The influence of the roof-grid on the electromagnetic field inside the building due to a direct lightning strike is shown. The values of the electromotive force induced in loops set at the most significant positions within the structure are calculated for six possible roof-grid configurations. The values of attenuation as a function of frequency and the geometric arrangement of the grid are also indicated. The presence of reinforced concrete walls is not directly taken into account.<<ETX>>","PeriodicalId":243730,"journal":{"name":"IEEE 1991 International Symposium on Electromagnetic Compatibility","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"EMC effects of the lightning protection system: shielding properties of the roof-grid\",\"authors\":\"S. Cristina, A. Orlandi\",\"doi\":\"10.1109/ISEMC.1991.148188\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A suitable set of parameters is used to evaluate the shielding performance of the roof-grid constituted by a mesh of conductors, electrically interconnected, laying on top of buildings with a large-area roof. The influence of the roof-grid on the electromagnetic field inside the building due to a direct lightning strike is shown. The values of the electromotive force induced in loops set at the most significant positions within the structure are calculated for six possible roof-grid configurations. The values of attenuation as a function of frequency and the geometric arrangement of the grid are also indicated. The presence of reinforced concrete walls is not directly taken into account.<<ETX>>\",\"PeriodicalId\":243730,\"journal\":{\"name\":\"IEEE 1991 International Symposium on Electromagnetic Compatibility\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 1991 International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1991.148188\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1991 International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1991.148188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
EMC effects of the lightning protection system: shielding properties of the roof-grid
A suitable set of parameters is used to evaluate the shielding performance of the roof-grid constituted by a mesh of conductors, electrically interconnected, laying on top of buildings with a large-area roof. The influence of the roof-grid on the electromagnetic field inside the building due to a direct lightning strike is shown. The values of the electromotive force induced in loops set at the most significant positions within the structure are calculated for six possible roof-grid configurations. The values of attenuation as a function of frequency and the geometric arrangement of the grid are also indicated. The presence of reinforced concrete walls is not directly taken into account.<>