RP-6透析器的体外表征:共电流和逆流间隙作为超滤的功能。

A Zelman, D Gisser
{"title":"RP-6透析器的体外表征:共电流和逆流间隙作为超滤的功能。","authors":"A Zelman,&nbsp;D Gisser","doi":"10.3109/08860227909063943","DOIUrl":null,"url":null,"abstract":"<p><p>Analytical and graphical techniques are described for presenting clearance data as a function of ultrafiltration; thus for the first time comparison of clearance values between dialyzers can be made unambiguously. This simple method uses a hand calculator to determine three coefficients. Clearance has been shown to be accurately described by the equation C = alpha 1 + alpha 2 Qv + alpha 3 (1/QBi). This formula permits construction of easily read families of curves which can predict clearance values under most clinical situations. The RP-6 dialyzer is characterized by these methods for clearance of urea, glucose and vitamin B 12 for counter-current and co-current modes.</p>","PeriodicalId":75998,"journal":{"name":"Journal of dialysis","volume":"3 2-3","pages":"237-50"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/08860227909063943","citationCount":"2","resultStr":"{\"title\":\"In vitro characterization of the RP-6 dialyzer: co-current and counter-current clearance as a function of ultrafiltration.\",\"authors\":\"A Zelman,&nbsp;D Gisser\",\"doi\":\"10.3109/08860227909063943\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Analytical and graphical techniques are described for presenting clearance data as a function of ultrafiltration; thus for the first time comparison of clearance values between dialyzers can be made unambiguously. This simple method uses a hand calculator to determine three coefficients. Clearance has been shown to be accurately described by the equation C = alpha 1 + alpha 2 Qv + alpha 3 (1/QBi). This formula permits construction of easily read families of curves which can predict clearance values under most clinical situations. The RP-6 dialyzer is characterized by these methods for clearance of urea, glucose and vitamin B 12 for counter-current and co-current modes.</p>\",\"PeriodicalId\":75998,\"journal\":{\"name\":\"Journal of dialysis\",\"volume\":\"3 2-3\",\"pages\":\"237-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/08860227909063943\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dialysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/08860227909063943\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dialysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/08860227909063943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

描述了将间隙数据作为超滤函数的分析和图形技术;因此,第一次可以明确地比较透析器之间的间隙值。这个简单的方法使用一个手持计算器来确定三个系数。间隙已被证明可以用等式C = α 1 + α 2 Qv + α 3 (1/QBi)来精确描述。该公式允许构建易于读取的曲线族,可以预测大多数临床情况下的清除率值。RP-6透析器的特点是在逆流和共流模式下清除尿素、葡萄糖和维生素b12。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro characterization of the RP-6 dialyzer: co-current and counter-current clearance as a function of ultrafiltration.

Analytical and graphical techniques are described for presenting clearance data as a function of ultrafiltration; thus for the first time comparison of clearance values between dialyzers can be made unambiguously. This simple method uses a hand calculator to determine three coefficients. Clearance has been shown to be accurately described by the equation C = alpha 1 + alpha 2 Qv + alpha 3 (1/QBi). This formula permits construction of easily read families of curves which can predict clearance values under most clinical situations. The RP-6 dialyzer is characterized by these methods for clearance of urea, glucose and vitamin B 12 for counter-current and co-current modes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信