CT检查中使用锡滤光片评价图像质量和辐射剂量

Tae-Gyu Song, Hee-Gon Lee, Jang-Seok Lee, Young-Ju Moon
{"title":"CT检查中使用锡滤光片评价图像质量和辐射剂量","authors":"Tae-Gyu Song, Hee-Gon Lee, Jang-Seok Lee, Young-Ju Moon","doi":"10.31320/jksct.2023.25.1.5","DOIUrl":null,"url":null,"abstract":"The Tin Filter used in CT scans in medical field has the effect of reducing patient exposure without deteriorating the image quality by block in low-energy X-rays (ranging 30-50 keV) generated from CT scanners. In this study, chest low-dose CT scans were performed with the lungman phantom and various low-dose scan protocol. Then, the image quality of acquired images were evaluated by comparing the radiation dose as to the use of tin filter. The performed evaluation showed that when performing CT scans with a Tin filter installed, the exposure dose was considerably reduced by removing low energy X-rays, but SNR and CNR decreased slightly. Therefore, it is significantly considered that the use of a tin filter in CT scans will help reduce the exposure dose as well as the patient dose while maintaining image quality.","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Image Quality and Radiation Dose according to Use of the Tin Filter during CT Examination\",\"authors\":\"Tae-Gyu Song, Hee-Gon Lee, Jang-Seok Lee, Young-Ju Moon\",\"doi\":\"10.31320/jksct.2023.25.1.5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Tin Filter used in CT scans in medical field has the effect of reducing patient exposure without deteriorating the image quality by block in low-energy X-rays (ranging 30-50 keV) generated from CT scanners. In this study, chest low-dose CT scans were performed with the lungman phantom and various low-dose scan protocol. Then, the image quality of acquired images were evaluated by comparing the radiation dose as to the use of tin filter. The performed evaluation showed that when performing CT scans with a Tin filter installed, the exposure dose was considerably reduced by removing low energy X-rays, but SNR and CNR decreased slightly. Therefore, it is significantly considered that the use of a tin filter in CT scans will help reduce the exposure dose as well as the patient dose while maintaining image quality.\",\"PeriodicalId\":272693,\"journal\":{\"name\":\"Korean Society of Computed Tomographic Technology\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Society of Computed Tomographic Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31320/jksct.2023.25.1.5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Society of Computed Tomographic Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31320/jksct.2023.25.1.5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

医学领域CT扫描中使用的锡滤光片在CT扫描仪产生的低能x射线(30-50 keV)中具有减少患者暴露而不影响图像质量的效果。在本研究中,胸部低剂量CT扫描与肺man幻像和各种低剂量扫描方案。然后,通过与使用锡滤光片的辐射剂量进行比较,评价所获取图像的图像质量。结果表明,在CT扫描中安装锡过滤器,去除低能x射线后,暴露剂量明显降低,但信噪比和CNR略有下降。因此,值得注意的是,在CT扫描中使用锡过滤器有助于减少暴露剂量和患者剂量,同时保持图像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Image Quality and Radiation Dose according to Use of the Tin Filter during CT Examination
The Tin Filter used in CT scans in medical field has the effect of reducing patient exposure without deteriorating the image quality by block in low-energy X-rays (ranging 30-50 keV) generated from CT scanners. In this study, chest low-dose CT scans were performed with the lungman phantom and various low-dose scan protocol. Then, the image quality of acquired images were evaluated by comparing the radiation dose as to the use of tin filter. The performed evaluation showed that when performing CT scans with a Tin filter installed, the exposure dose was considerably reduced by removing low energy X-rays, but SNR and CNR decreased slightly. Therefore, it is significantly considered that the use of a tin filter in CT scans will help reduce the exposure dose as well as the patient dose while maintaining image quality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信