模拟燃烧的天然气SO2和二氧化碳(IPP)东部龙目岛(50兆瓦)低成本煤模型所产生的致命气体的分布和百分比

Shafwan Amrullah, Sopyan Ali Rohman, Lalu Heri Rizaldi
{"title":"模拟燃烧的天然气SO2和二氧化碳(IPP)东部龙目岛(50兆瓦)低成本煤模型所产生的致命气体的分布和百分比","authors":"Shafwan Amrullah, Sopyan Ali Rohman, Lalu Heri Rizaldi","doi":"10.35970/jppl.v4i1.1193","DOIUrl":null,"url":null,"abstract":"The Sembelia Steam Power Plant is located in East Lombok, West Nusa Tenggara and is managed by PT. Lombok Energy Dynamic uses the light coal until 200,000 tons per year. This case can be the  environmental pollution. This study aims to calculate the SO2 and CO2 exhaust gases into the environment by the simulation as well as included the  fatality percentage due to coal combustion of the The Sembelia Steam Power Plant with the model of Gaussian. This research was carried out by calculating the SO2 and CO2concentrations released concentration. At the end of these project, we calculated the SO2 and CO2 released by the dispersion potential and fatality percentage at four points around it. The result of this research showed that the dispersion mass of SO2 dispersion was 0.096 kg per second (with distance of 2,000 to 46,000 m). This result showed that the increases (6.876x10-46 ppm to 1.276x10-5 ppm), and then showed that the decreases to 0 ppm. Fatality percentage in this study is 0 percent. The potential of  CO2 dispersion with an outgoing mass of 8,252 kg/second increased (2,000-58,000 m) with a concentration of 62.47x10-63 ppm to 7.9x10-4ppm. In the other hand, the concentration of CO2 was reduced to 0 ppm. In the end of this study showed that fatality percentage by the CO2 released is 0percent, and the calculation of dispersion at four points around the The Sembelia Steam Power Plant is safe from the SO2 and CO2dispersion.","PeriodicalId":351721,"journal":{"name":"Jurnal Pengendalian Pencemaran Lingkungan (JPPL)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulasi Penyebaran dan Persentase Fatalitas Oleh Gas SO2 dan CO2 Hasil Pembakaran PLTU Independent Power Producer (IPP) Lombok Timur (50 MW) Dengan Low Rank Coal Menggunakan Model Gaussian\",\"authors\":\"Shafwan Amrullah, Sopyan Ali Rohman, Lalu Heri Rizaldi\",\"doi\":\"10.35970/jppl.v4i1.1193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Sembelia Steam Power Plant is located in East Lombok, West Nusa Tenggara and is managed by PT. Lombok Energy Dynamic uses the light coal until 200,000 tons per year. This case can be the  environmental pollution. This study aims to calculate the SO2 and CO2 exhaust gases into the environment by the simulation as well as included the  fatality percentage due to coal combustion of the The Sembelia Steam Power Plant with the model of Gaussian. This research was carried out by calculating the SO2 and CO2concentrations released concentration. At the end of these project, we calculated the SO2 and CO2 released by the dispersion potential and fatality percentage at four points around it. The result of this research showed that the dispersion mass of SO2 dispersion was 0.096 kg per second (with distance of 2,000 to 46,000 m). This result showed that the increases (6.876x10-46 ppm to 1.276x10-5 ppm), and then showed that the decreases to 0 ppm. Fatality percentage in this study is 0 percent. The potential of  CO2 dispersion with an outgoing mass of 8,252 kg/second increased (2,000-58,000 m) with a concentration of 62.47x10-63 ppm to 7.9x10-4ppm. In the other hand, the concentration of CO2 was reduced to 0 ppm. In the end of this study showed that fatality percentage by the CO2 released is 0percent, and the calculation of dispersion at four points around the The Sembelia Steam Power Plant is safe from the SO2 and CO2dispersion.\",\"PeriodicalId\":351721,\"journal\":{\"name\":\"Jurnal Pengendalian Pencemaran Lingkungan (JPPL)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Pengendalian Pencemaran Lingkungan (JPPL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35970/jppl.v4i1.1193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Pengendalian Pencemaran Lingkungan (JPPL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35970/jppl.v4i1.1193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Sembelia蒸汽发电厂位于西努沙登加拉岛东龙目岛,由PT. Lombok Energy Dynamic管理,每年使用20万吨轻煤。这种情况下可造成环境污染。本研究旨在通过模拟计算排放到环境中的SO2和CO2废气,并采用高斯模型计算Sembelia蒸汽发电厂燃煤的死亡率。本研究通过计算SO2和co2的释放浓度进行。在这些项目结束时,我们计算了周围四个点的分散潜力和死亡率所释放的SO2和CO2。研究结果表明,SO2分散体的分散质量为0.096 kg / s(距离为2000 ~ 46000 m),从6.876 × 10-46 ppm增加到1.276 × 10-5 ppm,然后下降到0 ppm。该研究的死亡率为0%。从62.47 × 10-63 ppm到7.9 × 10-4ppm,输出质量为8252 kg/s的CO2分散潜力增加(2,000-58,000 m)。另一方面,二氧化碳的浓度降低到0 ppm。本研究最后表明,二氧化碳释放的死亡率为0%,Sembelia蒸汽发电厂周围四个点的分散计算是安全的,不受SO2和CO2分散的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulasi Penyebaran dan Persentase Fatalitas Oleh Gas SO2 dan CO2 Hasil Pembakaran PLTU Independent Power Producer (IPP) Lombok Timur (50 MW) Dengan Low Rank Coal Menggunakan Model Gaussian
The Sembelia Steam Power Plant is located in East Lombok, West Nusa Tenggara and is managed by PT. Lombok Energy Dynamic uses the light coal until 200,000 tons per year. This case can be the  environmental pollution. This study aims to calculate the SO2 and CO2 exhaust gases into the environment by the simulation as well as included the  fatality percentage due to coal combustion of the The Sembelia Steam Power Plant with the model of Gaussian. This research was carried out by calculating the SO2 and CO2concentrations released concentration. At the end of these project, we calculated the SO2 and CO2 released by the dispersion potential and fatality percentage at four points around it. The result of this research showed that the dispersion mass of SO2 dispersion was 0.096 kg per second (with distance of 2,000 to 46,000 m). This result showed that the increases (6.876x10-46 ppm to 1.276x10-5 ppm), and then showed that the decreases to 0 ppm. Fatality percentage in this study is 0 percent. The potential of  CO2 dispersion with an outgoing mass of 8,252 kg/second increased (2,000-58,000 m) with a concentration of 62.47x10-63 ppm to 7.9x10-4ppm. In the other hand, the concentration of CO2 was reduced to 0 ppm. In the end of this study showed that fatality percentage by the CO2 released is 0percent, and the calculation of dispersion at four points around the The Sembelia Steam Power Plant is safe from the SO2 and CO2dispersion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信