Adi Mustika
{"title":"ANALISIS KANDUNGAN KALIUM PADA AIR IRIGASI DI DAERAH IRIGASI GLUNDENGAN KECAMATAN WULUHAN KABUPATEN JEMBER","authors":"Adi Mustika","doi":"10.36526/biosense.v5i2.2241","DOIUrl":null,"url":null,"abstract":"Utilization of water for agricultural purposes is the highest, reaching 70% of the total utilization of water resources globally. In the Glundengan Irrigation Area, Wuluhan District, Jember Regency, with an area of ​​4996 ha, irrigation water is taken from the Bedadung River, and the excess water is discharged from the Glundengan Irrigation Area to the Bedadung River. This encourages research on the quality of irrigation water in these irrigation areas. This study aims to analyze the quality of irrigation water, especially the elemental content of potassium in the Glundengan irrigation channel. In the analysis of the quality of irrigation water, temporary sampling was carried out at two points, namely in the primary channel which carries water to the paddy fields and in the drainage channel which removes excess water from the irrigation area. The temperature and pH parameter analysis method used the standard SNI 6989.57:2008, while the K parameter analysis was carried out in the CDAST laboratory using the Flame Photometry-AAS method. The results of the analysis are compared with the water quality standards in Government Regulation No. 82 of 2001 (PP 82/2001): Management of Water Quality and Control of Water Pollution. The results of the analysis show that the temperature parameters in the primary and exhaust channels are 24°C respectively. The pH parameters in the primary and sewer channels were 7.5 and 7.2, respectively. The K parameters in the primary and sewer channels were 0.00593 mg/l and 0.00745 mg/l respectively, these figures were relatively small. These three parameters meet the water quality standards of Class II according to PP 82/2001.","PeriodicalId":325849,"journal":{"name":"JURNAL BIOSENSE","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JURNAL BIOSENSE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36526/biosense.v5i2.2241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

农业用水利用率最高,占全球水资源总利用率的70%。2月摄政武鹿汉区格伦登干灌区面积4996公顷,灌溉水从别大同河取水,多余的水从格伦登干灌区排入别大同河。这鼓励了对这些灌溉区灌溉水质量的研究。本研究旨在分析格伦登干灌溉渠灌溉水的水质,特别是钾元素含量。在灌溉水水质分析中,在两个点进行了临时采样,即在向稻田输水的主通道和从灌区排出多余水分的排水通道。温度和pH参数分析方法采用SNI 6989.57:2008标准,K参数分析在CDAST实验室采用火焰光度法-原子吸收光谱法进行。分析结果与2001年政府法规第82号(PP 82/2001):水质管理和水污染控制的水质标准进行了比较。分析结果表明,主通道和排气通道的温度参数分别为24℃。主槽和阴槽pH值分别为7.5和7.2。主槽和阴槽的K参数分别为0.00593 mg/l和0.00745 mg/l,数值较小。这三个参数符合PP 82/2001的二类水质标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ANALISIS KANDUNGAN KALIUM PADA AIR IRIGASI DI DAERAH IRIGASI GLUNDENGAN KECAMATAN WULUHAN KABUPATEN JEMBER
Utilization of water for agricultural purposes is the highest, reaching 70% of the total utilization of water resources globally. In the Glundengan Irrigation Area, Wuluhan District, Jember Regency, with an area of ​​4996 ha, irrigation water is taken from the Bedadung River, and the excess water is discharged from the Glundengan Irrigation Area to the Bedadung River. This encourages research on the quality of irrigation water in these irrigation areas. This study aims to analyze the quality of irrigation water, especially the elemental content of potassium in the Glundengan irrigation channel. In the analysis of the quality of irrigation water, temporary sampling was carried out at two points, namely in the primary channel which carries water to the paddy fields and in the drainage channel which removes excess water from the irrigation area. The temperature and pH parameter analysis method used the standard SNI 6989.57:2008, while the K parameter analysis was carried out in the CDAST laboratory using the Flame Photometry-AAS method. The results of the analysis are compared with the water quality standards in Government Regulation No. 82 of 2001 (PP 82/2001): Management of Water Quality and Control of Water Pollution. The results of the analysis show that the temperature parameters in the primary and exhaust channels are 24°C respectively. The pH parameters in the primary and sewer channels were 7.5 and 7.2, respectively. The K parameters in the primary and sewer channels were 0.00593 mg/l and 0.00745 mg/l respectively, these figures were relatively small. These three parameters meet the water quality standards of Class II according to PP 82/2001.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信