{"title":"DC 10:1带低温触点的哈蒙分压器","authors":"Kyu-Tae Kim, Sung-Won Kwon","doi":"10.1109/CPEM.1998.699803","DOIUrl":null,"url":null,"abstract":"A study on a DC Hamon divider with superconducting contacts (cryo-contacts Hamon divider) is described. The contact resistance error of the switch had been one of the most significant error sources in the conventional Hamon divider. A specially designed cryogenic switch made of Pb was used at liquid helium temperature for a series-parallel connection of the Hamon resistors which form the upper arm of a Wheatstone bridge for a self calibration. The 10:1 ratio uncertainty of the preliminary measurement is expected to easily reach a 0.1 ppm level.","PeriodicalId":239228,"journal":{"name":"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DC 10:1 Hamon divider with cryogenic contacts\",\"authors\":\"Kyu-Tae Kim, Sung-Won Kwon\",\"doi\":\"10.1109/CPEM.1998.699803\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A study on a DC Hamon divider with superconducting contacts (cryo-contacts Hamon divider) is described. The contact resistance error of the switch had been one of the most significant error sources in the conventional Hamon divider. A specially designed cryogenic switch made of Pb was used at liquid helium temperature for a series-parallel connection of the Hamon resistors which form the upper arm of a Wheatstone bridge for a self calibration. The 10:1 ratio uncertainty of the preliminary measurement is expected to easily reach a 0.1 ppm level.\",\"PeriodicalId\":239228,\"journal\":{\"name\":\"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.1998.699803\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.1998.699803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A study on a DC Hamon divider with superconducting contacts (cryo-contacts Hamon divider) is described. The contact resistance error of the switch had been one of the most significant error sources in the conventional Hamon divider. A specially designed cryogenic switch made of Pb was used at liquid helium temperature for a series-parallel connection of the Hamon resistors which form the upper arm of a Wheatstone bridge for a self calibration. The 10:1 ratio uncertainty of the preliminary measurement is expected to easily reach a 0.1 ppm level.