Daniela Díaz-Ravelo, Maite López-Simental, E. Alanís-Rodríguez
{"title":"康复和特殊教育中心的节能和质量项目","authors":"Daniela Díaz-Ravelo, Maite López-Simental, E. Alanís-Rodríguez","doi":"10.35429/jre.2019.8.3.16.22","DOIUrl":null,"url":null,"abstract":"The Centro de Rehabilitación y Educación Especial (CREE) required to look for alternatives to reduce the energy cost, so the DESMB methodology (Sifuentes, Martínez & Berumen, 2016) was used to find these alternatives. Energy dignostics type 1 and 2 were implementeda and they thrown as a result high consumption and current %THD above limit established by IEEE-519-1998 (Tellez, Eugenio, 2017); This previous analysis was required to know the condition of the electrical installation on the center and this locate different ways of contributing to its improvement, knowing the needs that are in the center, a solution was sought to the problems that would not affect its process; Based on this, it was decided to design a project of saving and quality of energy for it, through the sizing of passive tuned filters and a grid-connected photovoltaic system to generate economic savings.","PeriodicalId":329432,"journal":{"name":"Revista de Energías Renovables","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proyecto de ahorro y calidad de la energía en el centro de rehabilitación y educación especial\",\"authors\":\"Daniela Díaz-Ravelo, Maite López-Simental, E. Alanís-Rodríguez\",\"doi\":\"10.35429/jre.2019.8.3.16.22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Centro de Rehabilitación y Educación Especial (CREE) required to look for alternatives to reduce the energy cost, so the DESMB methodology (Sifuentes, Martínez & Berumen, 2016) was used to find these alternatives. Energy dignostics type 1 and 2 were implementeda and they thrown as a result high consumption and current %THD above limit established by IEEE-519-1998 (Tellez, Eugenio, 2017); This previous analysis was required to know the condition of the electrical installation on the center and this locate different ways of contributing to its improvement, knowing the needs that are in the center, a solution was sought to the problems that would not affect its process; Based on this, it was decided to design a project of saving and quality of energy for it, through the sizing of passive tuned filters and a grid-connected photovoltaic system to generate economic savings.\",\"PeriodicalId\":329432,\"journal\":{\"name\":\"Revista de Energías Renovables\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista de Energías Renovables\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35429/jre.2019.8.3.16.22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de Energías Renovables","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35429/jre.2019.8.3.16.22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
Rehabilitación y Educación特别中心(CREE)需要寻找降低能源成本的替代品,因此使用DESMB方法(Sifuentes, Martínez & Berumen, 2016)来寻找这些替代品。实施了类型1和类型2的能源诊断,并且由于高消耗和当前THD超过IEEE-519-1998规定的限制而抛出(Tellez, Eugenio, 2017);之前的分析是为了了解中心电气装置的状况,并找到有助于改进的不同方法,了解中心的需求,寻求不影响其过程的问题的解决方案;在此基础上,决定为其设计一个节能和节能的项目,通过无源调谐滤波器的尺寸和并网光伏系统来产生经济节约。
Proyecto de ahorro y calidad de la energía en el centro de rehabilitación y educación especial
The Centro de Rehabilitación y Educación Especial (CREE) required to look for alternatives to reduce the energy cost, so the DESMB methodology (Sifuentes, Martínez & Berumen, 2016) was used to find these alternatives. Energy dignostics type 1 and 2 were implementeda and they thrown as a result high consumption and current %THD above limit established by IEEE-519-1998 (Tellez, Eugenio, 2017); This previous analysis was required to know the condition of the electrical installation on the center and this locate different ways of contributing to its improvement, knowing the needs that are in the center, a solution was sought to the problems that would not affect its process; Based on this, it was decided to design a project of saving and quality of energy for it, through the sizing of passive tuned filters and a grid-connected photovoltaic system to generate economic savings.