在南非医院大规模实施太阳能热技术的潜力

A. Buckley
{"title":"在南非医院大规模实施太阳能热技术的潜力","authors":"A. Buckley","doi":"10.32638/PROCEEDINGS.ISEC2018.201807","DOIUrl":null,"url":null,"abstract":"1 SUMMARY This study investigates the potential for the large-scale roll-out and implementation of solar thermal (ST) technologies in South African hospitals to offset conventional fuel use and identifies challenges relating to this potential uptake. There are a total of 696 hospitals in South Africa (SA) with a total thermal energy demand for 20 hot water of 370 GWh per year. A total installed collector area of 73 972 m2 to 147 944 m2 across all hospitals in SA would increase the overall ST capacity of all these hospitals to compensate for 20 to 40% of their combined annual thermal energy demand. The major limiting factor for the uptake of ST technologies in South African hospitals is the current wide spread use of coal fired boilers as well as heat-pumps, making the adoption of ST technologies less feasible from a financial perspective. 25","PeriodicalId":424759,"journal":{"name":"Conference proceedings ISEC 2018","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"THE POTENTIAL OF LARGE-SCALE IMPLEMENTATION OF SOLAR THERMALTECHNOLOGIES IN SOUTH AFRICAN HOSPITALS\",\"authors\":\"A. Buckley\",\"doi\":\"10.32638/PROCEEDINGS.ISEC2018.201807\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"1 SUMMARY This study investigates the potential for the large-scale roll-out and implementation of solar thermal (ST) technologies in South African hospitals to offset conventional fuel use and identifies challenges relating to this potential uptake. There are a total of 696 hospitals in South Africa (SA) with a total thermal energy demand for 20 hot water of 370 GWh per year. A total installed collector area of 73 972 m2 to 147 944 m2 across all hospitals in SA would increase the overall ST capacity of all these hospitals to compensate for 20 to 40% of their combined annual thermal energy demand. The major limiting factor for the uptake of ST technologies in South African hospitals is the current wide spread use of coal fired boilers as well as heat-pumps, making the adoption of ST technologies less feasible from a financial perspective. 25\",\"PeriodicalId\":424759,\"journal\":{\"name\":\"Conference proceedings ISEC 2018\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference proceedings ISEC 2018\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32638/PROCEEDINGS.ISEC2018.201807\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference proceedings ISEC 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32638/PROCEEDINGS.ISEC2018.201807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究调查了南非医院大规模推广和实施太阳能热(ST)技术的潜力,以抵消传统燃料的使用,并确定了与这种潜力吸收相关的挑战。南非共有696家医院,每年对20个热水的总热能需求为370千兆瓦时。南南非所有医院安装的集热器总面积为73 972平方米至147 944平方米,将增加所有这些医院的总ST容量,以弥补其年热能需求的20%至40%。南非医院采用ST技术的主要限制因素是目前广泛使用燃煤锅炉和热泵,从财务角度来看,采用ST技术不太可行。25
本文章由计算机程序翻译,如有差异,请以英文原文为准。
THE POTENTIAL OF LARGE-SCALE IMPLEMENTATION OF SOLAR THERMALTECHNOLOGIES IN SOUTH AFRICAN HOSPITALS
1 SUMMARY This study investigates the potential for the large-scale roll-out and implementation of solar thermal (ST) technologies in South African hospitals to offset conventional fuel use and identifies challenges relating to this potential uptake. There are a total of 696 hospitals in South Africa (SA) with a total thermal energy demand for 20 hot water of 370 GWh per year. A total installed collector area of 73 972 m2 to 147 944 m2 across all hospitals in SA would increase the overall ST capacity of all these hospitals to compensate for 20 to 40% of their combined annual thermal energy demand. The major limiting factor for the uptake of ST technologies in South African hospitals is the current wide spread use of coal fired boilers as well as heat-pumps, making the adoption of ST technologies less feasible from a financial perspective. 25
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信