SF6脉冲高压同轴电缆中的气体替换

T. Stadlbauer, T. Kramer, D. Kontelis, L. Ducimetière, L. Sermeus, D. Woog
{"title":"SF6脉冲高压同轴电缆中的气体替换","authors":"T. Stadlbauer, T. Kramer, D. Kontelis, L. Ducimetière, L. Sermeus, D. Woog","doi":"10.1109/ICDL.2019.8796780","DOIUrl":null,"url":null,"abstract":"Several fast pulsed high voltage kicker systems at CERN use coaxial cables with SF6 gas as dielectric. Leak detection systems are installed and for interventions, the gas is recuperated and re-circulated, reducing emissions to a minimum. Nevertheless due to the high global warming potential of SF6 gas and the efforts of the European Union and CERN to reduce fluorinated greenhouse gas emissions to a minimum, a replacement strategy for the SF6 gas filled coaxial high voltage cables is being developed. New pulse generator technologies as well as different SF6 gas substitutes and also new conventional PE insulated cables are being studied. This paper gives an overview of the studies carried out to replace these cables. A comparison of possible alternatives with liquid, solid and gas dielectrics is given. The properties of the cables with alternative dielectrics are outlined, by either measurement, simulation or calculation.Especially the important parameters for kicker systems are evaluated and compared: breakdown voltage, low attenuation and low impedance change. Possible dimensions and tolerances are given, the expected costs and environmental impact are outlined. In addition an overview of different dielectric liquids used in the complete pulse generator as well as the operational experience, performance and limitations is given.","PeriodicalId":102217,"journal":{"name":"2019 IEEE 20th International Conference on Dielectric Liquids (ICDL)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"SF6 Gas Replacement in Pulsed High Voltage Coaxial Cables\",\"authors\":\"T. Stadlbauer, T. Kramer, D. Kontelis, L. Ducimetière, L. Sermeus, D. Woog\",\"doi\":\"10.1109/ICDL.2019.8796780\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Several fast pulsed high voltage kicker systems at CERN use coaxial cables with SF6 gas as dielectric. Leak detection systems are installed and for interventions, the gas is recuperated and re-circulated, reducing emissions to a minimum. Nevertheless due to the high global warming potential of SF6 gas and the efforts of the European Union and CERN to reduce fluorinated greenhouse gas emissions to a minimum, a replacement strategy for the SF6 gas filled coaxial high voltage cables is being developed. New pulse generator technologies as well as different SF6 gas substitutes and also new conventional PE insulated cables are being studied. This paper gives an overview of the studies carried out to replace these cables. A comparison of possible alternatives with liquid, solid and gas dielectrics is given. The properties of the cables with alternative dielectrics are outlined, by either measurement, simulation or calculation.Especially the important parameters for kicker systems are evaluated and compared: breakdown voltage, low attenuation and low impedance change. Possible dimensions and tolerances are given, the expected costs and environmental impact are outlined. In addition an overview of different dielectric liquids used in the complete pulse generator as well as the operational experience, performance and limitations is given.\",\"PeriodicalId\":102217,\"journal\":{\"name\":\"2019 IEEE 20th International Conference on Dielectric Liquids (ICDL)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 20th International Conference on Dielectric Liquids (ICDL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDL.2019.8796780\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 20th International Conference on Dielectric Liquids (ICDL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2019.8796780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

欧洲核子研究中心的几个快脉冲高压踢子系统使用SF6气体作为介质的同轴电缆。安装了泄漏检测系统,对于干预措施,气体被回收并再循环,将排放量降至最低。然而,由于SF6气体具有很高的全球变暖潜势,以及欧洲联盟和欧洲核子研究中心努力将氟化温室气体的排放降至最低限度,目前正在制定SF6气体同轴高压电缆的替代战略。新的脉冲发生器技术以及不同的SF6气体替代品和新的传统PE绝缘电缆正在研究中。本文概述了为取代这些电缆而进行的研究。对液体、固体和气体介质的可能替代品进行了比较。通过测量、模拟或计算,概述了可选介质电缆的性能。特别是对踢脚系统的重要参数:击穿电压、低衰减和低阻抗变化进行了评价和比较。给出了可能的尺寸和公差,概述了预期成本和环境影响。此外,还概述了在整个脉冲发生器中使用的不同介质液体及其运行经验、性能和局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SF6 Gas Replacement in Pulsed High Voltage Coaxial Cables
Several fast pulsed high voltage kicker systems at CERN use coaxial cables with SF6 gas as dielectric. Leak detection systems are installed and for interventions, the gas is recuperated and re-circulated, reducing emissions to a minimum. Nevertheless due to the high global warming potential of SF6 gas and the efforts of the European Union and CERN to reduce fluorinated greenhouse gas emissions to a minimum, a replacement strategy for the SF6 gas filled coaxial high voltage cables is being developed. New pulse generator technologies as well as different SF6 gas substitutes and also new conventional PE insulated cables are being studied. This paper gives an overview of the studies carried out to replace these cables. A comparison of possible alternatives with liquid, solid and gas dielectrics is given. The properties of the cables with alternative dielectrics are outlined, by either measurement, simulation or calculation.Especially the important parameters for kicker systems are evaluated and compared: breakdown voltage, low attenuation and low impedance change. Possible dimensions and tolerances are given, the expected costs and environmental impact are outlined. In addition an overview of different dielectric liquids used in the complete pulse generator as well as the operational experience, performance and limitations is given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信