在自由浮动的毫米大小的大脑植入物之间进行数据通信的电容链路

Xiao Sha, PuYang Zheng, Yasha Karimi, M. Stanaćević
{"title":"在自由浮动的毫米大小的大脑植入物之间进行数据通信的电容链路","authors":"Xiao Sha, PuYang Zheng, Yasha Karimi, M. Stanaćević","doi":"10.1109/MeMeA52024.2021.9478592","DOIUrl":null,"url":null,"abstract":"Establishing communication between free floating brain implants is critical in applications that require a population of implants to operate in an organized manner or in a real-time feedback loop. We present a feasibility study of a data transmission link between mm-sized free floating brain implants through capacitive coupling. The proposed capacitive link utilizes metal plates integrated on a bottom and a sidewall of the implant. We demonstrate that the minimum required input power for establishing the data link is 31 nW at the operating frequency of 915 MHz. We demonstrate the feasibility of the data link up to a distance of 2 mm between the implants.","PeriodicalId":429222,"journal":{"name":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Capacitive Link for Data Communication Between Free Floating mm-sized Brain Implants\",\"authors\":\"Xiao Sha, PuYang Zheng, Yasha Karimi, M. Stanaćević\",\"doi\":\"10.1109/MeMeA52024.2021.9478592\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Establishing communication between free floating brain implants is critical in applications that require a population of implants to operate in an organized manner or in a real-time feedback loop. We present a feasibility study of a data transmission link between mm-sized free floating brain implants through capacitive coupling. The proposed capacitive link utilizes metal plates integrated on a bottom and a sidewall of the implant. We demonstrate that the minimum required input power for establishing the data link is 31 nW at the operating frequency of 915 MHz. We demonstrate the feasibility of the data link up to a distance of 2 mm between the implants.\",\"PeriodicalId\":429222,\"journal\":{\"name\":\"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA52024.2021.9478592\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA52024.2021.9478592","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在需要大量植入物以有组织的方式或在实时反馈回路中操作的应用中,在自由浮动的大脑植入物之间建立通信是至关重要的。我们提出了一种通过电容耦合在毫米大小的自由浮动脑植入物之间建立数据传输链路的可行性研究。所建议的电容连接利用集成在植入物的底部和侧壁上的金属板。我们证明,在915 MHz的工作频率下,建立数据链路所需的最小输入功率为31 nW。我们演示了数据链在植入物之间2毫米距离的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Capacitive Link for Data Communication Between Free Floating mm-sized Brain Implants
Establishing communication between free floating brain implants is critical in applications that require a population of implants to operate in an organized manner or in a real-time feedback loop. We present a feasibility study of a data transmission link between mm-sized free floating brain implants through capacitive coupling. The proposed capacitive link utilizes metal plates integrated on a bottom and a sidewall of the implant. We demonstrate that the minimum required input power for establishing the data link is 31 nW at the operating frequency of 915 MHz. We demonstrate the feasibility of the data link up to a distance of 2 mm between the implants.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信