计算机技术在医学应用中的可靠性和安全性分析

Barry W. Johnson, J. Aylor
{"title":"计算机技术在医学应用中的可靠性和安全性分析","authors":"Barry W. Johnson, J. Aylor","doi":"10.1109/ECBS.1988.5453","DOIUrl":null,"url":null,"abstract":"Analysis approaches that can be used in the design of computer-based systems for medical applications are described. The major contributions are the definition of safety and the development of analysis techniques which allow safety to be quantified. The results presented are of particular importance in medical applications where the inappropriate operation of the computer system can be catastrophic. A microprocessor-based controller developed for an electric wheelchair is described and used as an example to illustrate the basic concepts and modeling techniques. The results demonstrate that reliability considerations alone are insufficient to evaluate the effectiveness of a given design; safety must also be considered to ensure that the best design is selected for a given application.<<ETX>>","PeriodicalId":291071,"journal":{"name":"Proceedings of the Symposium on the Engineering of Computer-Based Medical","volume":"37 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Reliability and safety analysis in medical applications of computer technology\",\"authors\":\"Barry W. Johnson, J. Aylor\",\"doi\":\"10.1109/ECBS.1988.5453\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Analysis approaches that can be used in the design of computer-based systems for medical applications are described. The major contributions are the definition of safety and the development of analysis techniques which allow safety to be quantified. The results presented are of particular importance in medical applications where the inappropriate operation of the computer system can be catastrophic. A microprocessor-based controller developed for an electric wheelchair is described and used as an example to illustrate the basic concepts and modeling techniques. The results demonstrate that reliability considerations alone are insufficient to evaluate the effectiveness of a given design; safety must also be considered to ensure that the best design is selected for a given application.<<ETX>>\",\"PeriodicalId\":291071,\"journal\":{\"name\":\"Proceedings of the Symposium on the Engineering of Computer-Based Medical\",\"volume\":\"37 6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Symposium on the Engineering of Computer-Based Medical\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECBS.1988.5453\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Symposium on the Engineering of Computer-Based Medical","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECBS.1988.5453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

分析方法,可用于设计计算机为基础的系统为医疗应用程序进行了描述。主要的贡献是安全的定义和分析技术的发展,使安全可以量化。所提出的结果在医疗应用中具有特别重要的意义,其中计算机系统的不当操作可能是灾难性的。描述了一种基于微处理器的电动轮椅控制器,并以实例说明了基本概念和建模技术。结果表明,仅考虑可靠性不足以评估给定设计的有效性;还必须考虑安全性,以确保为给定应用选择最佳设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability and safety analysis in medical applications of computer technology
Analysis approaches that can be used in the design of computer-based systems for medical applications are described. The major contributions are the definition of safety and the development of analysis techniques which allow safety to be quantified. The results presented are of particular importance in medical applications where the inappropriate operation of the computer system can be catastrophic. A microprocessor-based controller developed for an electric wheelchair is described and used as an example to illustrate the basic concepts and modeling techniques. The results demonstrate that reliability considerations alone are insufficient to evaluate the effectiveness of a given design; safety must also be considered to ensure that the best design is selected for a given application.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信