A. Melninkaitis, D. Mikšys, R. Grigonis, V. Sirutkaitis, M. Jupé, D. Ristau
{"title":"高反射镜中激光损伤阈值测量的比较研究","authors":"A. Melninkaitis, D. Mikšys, R. Grigonis, V. Sirutkaitis, M. Jupé, D. Ristau","doi":"10.1117/12.753705","DOIUrl":null,"url":null,"abstract":"S-on-1 laser-induced damage threshold (LIDT) dependence on the pulse duration at two different wavelengths was experimentally investigated in metallic and dielectric laser mirrors. LIDT's of high-reflective dielectric coatings made of alternating λ/4 layers of TiO2/SiO2 and Ta2O5/SiO2 and those of protected metallic Au and Ag coatings were tested at 800 nm and 400 nm wavelengths with Ti:Sapphire laser pulses of 46 fs, 130 fs and 1.8 ps duration. S-on-1 measurements were performed according to international ISO 11254-2 standard using 10000 pulses/per site and compared with 1-on-1 measurements.","PeriodicalId":204978,"journal":{"name":"SPIE Laser Damage","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comparative studies of laser-induced damage threshold measurements in highly reflecting mirrors\",\"authors\":\"A. Melninkaitis, D. Mikšys, R. Grigonis, V. Sirutkaitis, M. Jupé, D. Ristau\",\"doi\":\"10.1117/12.753705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"S-on-1 laser-induced damage threshold (LIDT) dependence on the pulse duration at two different wavelengths was experimentally investigated in metallic and dielectric laser mirrors. LIDT's of high-reflective dielectric coatings made of alternating λ/4 layers of TiO2/SiO2 and Ta2O5/SiO2 and those of protected metallic Au and Ag coatings were tested at 800 nm and 400 nm wavelengths with Ti:Sapphire laser pulses of 46 fs, 130 fs and 1.8 ps duration. S-on-1 measurements were performed according to international ISO 11254-2 standard using 10000 pulses/per site and compared with 1-on-1 measurements.\",\"PeriodicalId\":204978,\"journal\":{\"name\":\"SPIE Laser Damage\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SPIE Laser Damage\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.753705\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPIE Laser Damage","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.753705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparative studies of laser-induced damage threshold measurements in highly reflecting mirrors
S-on-1 laser-induced damage threshold (LIDT) dependence on the pulse duration at two different wavelengths was experimentally investigated in metallic and dielectric laser mirrors. LIDT's of high-reflective dielectric coatings made of alternating λ/4 layers of TiO2/SiO2 and Ta2O5/SiO2 and those of protected metallic Au and Ag coatings were tested at 800 nm and 400 nm wavelengths with Ti:Sapphire laser pulses of 46 fs, 130 fs and 1.8 ps duration. S-on-1 measurements were performed according to international ISO 11254-2 standard using 10000 pulses/per site and compared with 1-on-1 measurements.