人工晶状体质量自动评估的实验设置和方法

Andrea Cigaina, G. Fenu, F. A. Pellegrino, P. Sirotti, S. Rinaldi, D. Tognetto
{"title":"人工晶状体质量自动评估的实验设置和方法","authors":"Andrea Cigaina, G. Fenu, F. A. Pellegrino, P. Sirotti, S. Rinaldi, D. Tognetto","doi":"10.1109/ISPA.2013.6703824","DOIUrl":null,"url":null,"abstract":"Intraocular lenses (IOLs) are widely used in cataract surgery. There is a variety of IOLs depending on lens material, optical and mechanical design. Evaluation of the visual performance obtainable with intraocular lenses is important for objective comparison between IOL models. Indeed, the visual performance of implanted lenses has a deep impact on the life of the subjects, having medical, social and economical consequences. The purpose of the present paper is twofold: first, we propose an experimental setup, consisting of an actuated opto-electro-mechanical eye capable of simulating different refractive and optical conditions. Second, we suggest to employ some well-known image quality assessment tools for evaluating the visual performance of different IOLs (or of the same IOL in different conditions) based on the comparison between the original image and that produced by the artificial eye equipped with the IOL. The objective and repeatable results obtained, are in accordance with subjective evaluation (a time-consuming procedure employed in previous works).","PeriodicalId":425029,"journal":{"name":"2013 8th International Symposium on Image and Signal Processing and Analysis (ISPA)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental setup and methodology for automatic quality assessment of intraocular lenses\",\"authors\":\"Andrea Cigaina, G. Fenu, F. A. Pellegrino, P. Sirotti, S. Rinaldi, D. Tognetto\",\"doi\":\"10.1109/ISPA.2013.6703824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Intraocular lenses (IOLs) are widely used in cataract surgery. There is a variety of IOLs depending on lens material, optical and mechanical design. Evaluation of the visual performance obtainable with intraocular lenses is important for objective comparison between IOL models. Indeed, the visual performance of implanted lenses has a deep impact on the life of the subjects, having medical, social and economical consequences. The purpose of the present paper is twofold: first, we propose an experimental setup, consisting of an actuated opto-electro-mechanical eye capable of simulating different refractive and optical conditions. Second, we suggest to employ some well-known image quality assessment tools for evaluating the visual performance of different IOLs (or of the same IOL in different conditions) based on the comparison between the original image and that produced by the artificial eye equipped with the IOL. The objective and repeatable results obtained, are in accordance with subjective evaluation (a time-consuming procedure employed in previous works).\",\"PeriodicalId\":425029,\"journal\":{\"name\":\"2013 8th International Symposium on Image and Signal Processing and Analysis (ISPA)\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 8th International Symposium on Image and Signal Processing and Analysis (ISPA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISPA.2013.6703824\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 8th International Symposium on Image and Signal Processing and Analysis (ISPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPA.2013.6703824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

人工晶状体(iol)广泛应用于白内障手术。根据晶状体材料、光学和机械设计的不同,有多种iol。评估人工晶状体的视觉性能对于人工晶状体模型之间的客观比较是重要的。事实上,植入镜片的视觉表现对受试者的生活产生了深刻的影响,产生了医疗、社会和经济后果。本文的目的有两个:首先,我们提出了一个实验装置,由一个能够模拟不同折射和光学条件的驱动光电机械眼组成。其次,我们建议使用一些知名的图像质量评估工具,根据原始图像与安装IOL的人工眼产生的图像的比较来评估不同IOL(或不同条件下相同IOL)的视觉性能。所获得的客观和可重复的结果与主观评价(在以前的工作中采用了一个耗时的过程)一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental setup and methodology for automatic quality assessment of intraocular lenses
Intraocular lenses (IOLs) are widely used in cataract surgery. There is a variety of IOLs depending on lens material, optical and mechanical design. Evaluation of the visual performance obtainable with intraocular lenses is important for objective comparison between IOL models. Indeed, the visual performance of implanted lenses has a deep impact on the life of the subjects, having medical, social and economical consequences. The purpose of the present paper is twofold: first, we propose an experimental setup, consisting of an actuated opto-electro-mechanical eye capable of simulating different refractive and optical conditions. Second, we suggest to employ some well-known image quality assessment tools for evaluating the visual performance of different IOLs (or of the same IOL in different conditions) based on the comparison between the original image and that produced by the artificial eye equipped with the IOL. The objective and repeatable results obtained, are in accordance with subjective evaluation (a time-consuming procedure employed in previous works).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信